Niles RVL-6 Installation & Operation Manual page 11

Modular multi-room controller
Hide thumbs Also See for RVL-6:
Table of Contents

Advertisement

INTELLIPAD
RP-6 / IRR4D+
Making the IR Sensor/Keypad Connections
• CAUTION: Power to the RVL-6 and amplifier must be disconnected.
• For your convenience, all SENSOR input connectors on the RVL-6 are removable.
• Strip 3/8" of insulation from the end of each wire.
• Tightly twist each wire end until there are no frayed ends.
• Insert each wire into the appropriate hole on the connector terminals using the sensor/keypad wiring con-
vention (see Figure 9).
• Tighten the screws which lock the wire into place. Be certain that the polarity labels on the rear of the RVL-6
are precisely followed.
Pin 1 = Red (+12V DC) Pin 2 = Bare (Ground) Pin 3 = Black (DATA)
MS-2
MS-2
RP-6
Figure 8 Home running IR sensors/keypads.
D
G
A
12
N
T
V
D
A
Red
Drain (shield)
SENSOR/KEYPAD WIRING CONNECTION
Figure 9
11
MS-2
RP-6
Black
MS-1
RP-6
RP-6 / IRR4D+