Retrofit Installation
14
Install Bulbs
1
WARNING
Before servicing or cleaning unit,
switch power off at service panel and lock the service
disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.

Operation

To Operate Fan
Use an on/off switch to operate this ventilator. Use of speed
controls may cause a motor humming noise.
To Operate Lights
The light and night light can be operated independently,
using separate on/off switches.
2
RN80LC
3
4

Cleaning and Maintenance

To Clean
For quiet and efficient operation, long life and attractive
appearance, remove Grille and vacuum interior of unit with
a dusting brush attachment.
The Motor is permanently lubricated and never needs oiling.
If the motor bearings are making excessive or unusual
noises, replace the Motor.
To change bulbs
Refer to Retrofit Installation
Step 14 (above).
1. Carefully insert a small
flathead screwdriver between
the Grille and Lens, then
twist to remove Lens.
2. Purchase two (2) 18W (max.)
type GU24 fluorescent
lamps with Maximum Overall
Length (MOL) of
3.9" (100 mm).
Purchase a 4W (max.)
C7-type incandescent night light bulb.
3. Insert bulbs into their sockets. Replace Lens.