RADIATION DAMPER
ACCESSORY KIT
READ AND SAVE THESE INSTRUCTIONS
For Use in 1, 2 or 3 Hour Rated Floor-Ceiling and Roof-Ceiling Designs.
Horizontal Mount Only.
For use with the following ventilation fan models:
• Broan DX90, DX110, HD50, HD80, 676, 676EX, 683, 683C, 684, 770, 784
• NuTone HD50NT, HD80NT, NT080C, 50NT, 80NT, 671SP, 672SP, 684NT
The following components are included with this accessory
kit:
(1) Radiation Damper Assembly
(1) Metal Duct Connector
(1) Metal Fan Grille
(2) Slide Channels
(4) Support Angles
(1) Plaster Guard
Parts Bag Containing:
(8) #8-18 x 0.375" Screws
(2) #8-18 x 0.812" Screws
Identify the following ventilation fan (purchased
separately) components and discard:
• Plastic Fan Grille Assembly
• Plastic Duct Connector Assembly
Assemble slide channels, support angles and duct
connector to ventilation fan housing: (Fig. 1)
1. Snap metal duct connector onto housing. Make
sure that tabs on the duct connector lock into the
slots on the housing. Damper flap hinge should be
positioned toward top of housing.
2. Attach the (2) slide channels to the housing using
(4) #8-18 x 0.375" sheet metal screws (provided).
The slide channel position can be adjusted to
accommodate different ceiling material thicknesses.
3. Insert (2) support angles into each slide channel.
Assemble radiation damper to fan housing: (Fig. 2)
4. Position radiation damper on the inlet side of the
fan so the arrow shown on spec label in the damper
points UP in the finished installation. Attach the
damper to the fan using (4) #8-18 x 0.375" sheet
metal screws (provided). There must be a minimum
of two connections on each of two opposite sides.
Take care to ensure that the fasteners do not
interfere with the closing of the damper curtain.
METAL DUCT
CONNECTOR
HOUSING
MODEL RDJ1
Page 1
SUPPORT
ANGLE
SLIDE
CHANNEL
FIG. 1
RADIATION
DAMPER
ASSEMBLY
FIG. 2

Advertisement

loading

Summary of Contents for NuTone RDJ1

  • Page 1 For use with the following ventilation fan models: • Broan DX90, DX110, HD50, HD80, 676, 676EX, 683, 683C, 684, 770, 784 • NuTone HD50NT, HD80NT, NT080C, 50NT, 80NT, 671SP, 672SP, 684NT The following components are included with this accessory kit:...
  • Page 2 MODEL RDJ1 Page 2 INSTALLATION CLASSIFIED SEE DETAILS ON UL INSTRUCTIONS CLASSIFICATION MARKING ON PRODUCT 5. Plan installation so that ceiling penetration is located within ceiling tiles or panels without necessitating cuts in any ceiling suspension main runners or cross tees.
  • Page 3 MODEL RDJ1 Page 3 WARNOCK HERSEY WARNOCK HERSEY LISTING INSTALLATION INSTRUCTIONS INCLUDES DAMPER ONLY. IT DOES NOT INCLUDE EXHAUST FAN. DAMPERS MAY BE USED 5. Position fan/damper assembly so that the inlet face of WITH UL LISTED FAN MODELS the radiation damper is flush with the finished surface of NOTED.
  • Page 4: Service Parts

    LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
  • Page 5 À utiliser avec les modèles de ventilateurs d’aération suivants : • Broan DX90, DX110, HD50, HD80, 676, 676EX, 683, 683C, 684, 770, 784 • NuTone HD50NT, HD80NT, NT080C, 50NT, 80NT, 671SP, 672SP, 684NT Cet ensemble comprend les pièces suivantes :...
  • Page 6 MODÈLE RDJ1 Page 6 DIRECTIVES HOMOLOGUÉ VOIR LES DÉTAILS D’INSTALLATION DE L’HOMOLOGATION UL SUR L’ÉTIQUETTE DU PRODUIT 5. Prévoyez l’installation de manière à ce que le point d’entrée soit situé dans un carreau ou un panneau du plafond sans avoir à couper aucun élément de la structure de suspension.
  • Page 7 MODÈLE RDJ1 Page 7 DIRECTIVES D’INSTALLATION L’HOMOLOGATION WARNOCK HERSEY NE COMPREND QUE WARNOCK HERSEY LE CLAPET. ELLE N’INCLUT PAS LE VENTILATEUR D’ÉVACUATION. LE CLAPET PEUT ÊTRE UTILISÉ 5. Positionnez l’assemblage ventilateur/clapet de sorte que AVEC LES MODÈLES DE l’entrée du clapet anti-rayonnement affleure la surface HOMOLOGATION WARNOCK VENTILATEURS HOMOLOGUÉS UL.
  • Page 8: Pièces De Rechange

    GARANTIE LIMITÉE D’UN AN BROAN-NUTONE Broan-NuTone garantit à l’acheteur original que les produits vendus en vertu de la présente sont libres de tout vice de matériau ou de fabrication pour une période d’un an à compter de la date d’achat originale. CETTE GARANTIE NE COMPORTE AUCUNE AUTRE GARANTIE, EXPRESSE OU TACITE, Y COMPRIS, MAIS SANS S’Y LIMITER, LES GARANTIES TACITES DE VALEUR MARCHANDE OU D’...
  • Page 9 Para usarse con los siguientes modelos de ventilador: • Broan DX90, DX110, HD50, HD80, 676, 676EX, 683, 683C, 684, 770, 784 • NuTone HD50NT, HD80NT, NT080C, 50NT, 80NT, 671SP, 672SP, 684NT Con este juego de accesorios se incluyen los siguientes...
  • Page 10 MODELO RDJ1 Página 10 INSTRUCCIONES DE CLASIFICADO VEA LOS DETALLES INSTALACIÓN SEGÚN EN LA MARCA DE CLASIFICACIÓN UL DEL PRODUCTO 5. Planee la instalación de tal modo que la abertura en el cielo raso quede ubicada entre los azulejos o paneles del cielo raso sin necesidad de hacer cortes en T transversales ni en vigas principales de suspensión.
  • Page 11 MODELO RDJ1 Página 11 INSTRUCCIONES DE LA APROBACIÓN DE WARNOCK HERSEY INCLUYE INSTALACIÓN SEGÚN ÚNICAMENTE AL REGULADOR. NO INCLUYE AL VENTILADOR DE EXTRACCIÓN. SE PUEDEN WARNOCK HERSEY USAR LOS REGULADORES CON LOS MODELOS DE VENTILADOR APROBADO POR APROBADOS POR UL SEÑALADOS. 5. Coloque el conjunto de ventilador y regulador de tal WARNOCK HERSEY modo que la cara de entrada del regulador de radiación...
  • Page 12: Piezas De Servicio

    Para calificar para la garantía de servicio, usted debe (a) notificar a Broan-NuTone al domicilio o al número de teléfono que se menciona abajo, (b) dar el número del modelo y la identificación de la pieza, y (c) describir la naturaleza de cualquier defecto en el producto o la pieza. En el momento de solicitar servicio cubierto por la garantía, usted debe de presentar un comprobante con la fecha original de compra.