Step 4
Use the Torx T10-Security tool to unscrew the bolt holding the 5w laser unit in place.
When you are looking down from the top, turn the tool clockwise to undo the bolt.
Unscrew bold holding 5w laser unit in place.
Once the bold has been removed, slide the laser unit upwards to release it from the
bracket.
5W Laser Unit removed.