3.2 Pre-Installation checks

Please read the WiLAS System User Operations
Guide thoroughly before commencing installation
Your WiLAS system has been preconfigured prior to shipment. One Control Station is configured as a
"Master" Control Station, all others being configured as "Slave" Control Stations. Similarly, one WiLAS
Remote Control (or fixed Control panel) is configured as a "Master" with all others configured as Slaves.
There is only one Master Remote per network. The number of Slave Control Stations and Slave Remotes
will depend on the number of Control Stations specified by the site survey.
Before permanently installing any equipment, it should be verified that:
The designated position for the Master Control Station is readily
accessible and in close proximity to the main office (or other appropriate
central building).
Each individual Control Station (or optional Beacon Light Station) is sited
within 300 metres of at least one other Control Station. Ideally 2 or
more stations should be within the 300m range.
The proposed location of the Sirens and Control Stations provide
satisfactory audio coverage and remote signal reception (line of sight
between antennae is desirable).