INSTALLING & CLEANING FOAM WET FILTER
1
INSTALLING FOAM WET FILTER
1. Verify that the power cord is disconnected from the outlet (Fig. 1).
2. Remove the power head and place in an upside-down position. Follow instructions to remove
the reusable cloth filter on page 14.
3. Carefully slide the foam wet filter over the filter cage making sure the cage is completely
covered (Fig. 2 & 3).
4. Place the power head onto the collection tank.
CLEANING FOAM WET FILTER
1. With the removed power head in an upside-down position, carefully remove the foam wet filter (Fig. 4).
2. Use a mild soap and water solution to wash the foam wet filter and rinse with clean water (Fig. 5).
3. Allow the filter to air dry for 24 hours before installing onto the filter cage.
WARNING:TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE

TROUBLESHOOTING.

PROBLEM
The wet/dry vacuum will not
operate.
The dust comes out from the
motor cover.
Reduced efficiency and motor/
speed vibration.
2
3
TROUBLESHOOTING
POSSIBLE CAUSE
No power supply.
Faulty power cord.
Collection tank is full.
Switch in the wrong position.
The reusable cloth filter is
missing or damaged.
There are blockages in the
nozzle, hose, or the collection
tank inlets.
The reusable cloth filter is
clogged by fine dust.
4
SOLUTION
Check the power supply, cord,
breakers, and fuses.
Unplug and check the power
cord. If damaged, have it
repaired by a professional.
Empty the collection tank.
Press the ON 'I' button on the
power head.
Attach or replace the reusable
cloth filter.
Unplug and check nozzle,
hose and collection tank inlets
for blockages.
Take off the filter and clean it or
install a new reusable cloth filter.