Rheem GHE119SS Use & Care Manual page 49

Commercial high efficiency water heater
Hide thumbs Also See for GHE119SS:
Table of Contents

Advertisement

Before You Call For Service...
Alarm ('A')
and Alert
('T') Codes
Anode "short" circuited. This can be caused by wiring
T130
damage, anode damage, or the anode in contact with
the tank.
Anode power = 100%. The anode system has reached
T131
its protective limits on one or more anode elements.
Anode power > 70%. The anode system is approaching
T132
its protective limits on one or more anode elements.
Anode "open" circuit. This can be caused by wiring
T133
damage, wiring disconnected, or anode damage.
Anode control common and the power connection for
T134
this anode cross connected.
Anode "short" circuited. This can be caused by wiring
T135
damage, anode damage, or the anode in contact with
the tank.
Anode power = 100%. The anode system has reached
T136
its protective limits on one or more anode elements.
Anode power > 70%. The anode system is approaching
T137
its protective limits on one or more anode elements.
Anode "open" circuit which could be caused by wiring
T138
damage, wiring disconnected or anode damage.
Anode "short" circuited which could be caused by wiring
damage, anode damage or the anode is in contact with
T140
the tank. This is not a connector issue and not caused
from leaking. This can only be a failed anode.
Anode power ≥ 100% and has reached its protective
T141
limit.
Anode power > 87% but < 100%. The anode is ap-
T142
proaching its protective limit.
Description
49
Current Alarm Screen Display
T130 Middle Anode Shorted
->Check wiring connections for the middle anode.
If error persists, please contact technical support or
service provider.
T131 Middle Anode Overload
->Middle Anode has reached full capacity. Tank
may not be fully protected. Contact technical support or
service provider.
T132 Middle Anode Pre-Overload
->Middle Anode near end of useful life but will con-
tinue protecting tank. Please contact technical support.
T133 Lower Anode Open
->Check wiring connections for the upper anode.
If error persists, please contact technical support or
service provider.
T134 Lower Anode Mounting Error
->Check wiring connections for the lower anode.
If error persists, please contact technical support or
service provider.
T135 Lower Anode Shorted
->Check wiring connections for the lower anode.
If error persists, please contact technical support or
service provider.
T136 Lower Anode Overload
->Lower Anode has reached full capacity. Tank may
not be fully protected. Contact technical support or
service provider.
T137 Lower Anode Pre-Overload
->Lower Anode near end of useful life but will con-
tinue protecting tank. Please contact technical support.
T138 Anode 4 Open
->Check wiring connections for anode #4. If error
persists, please contact technical support or service
provider.
T140 Anode 4 Shorted
->Check wiring connections for anode #4. If error
persists, please contact technical support or service
provider.
T141 Anode 4 Overload
->Anode #4 has reached full capacity. Tank may not
be fully protected. Contact technical support or service
provider.
T142 Anode 4 Pre-Overload
->Anode #4 has reached full capacity. Tank may not
be fully protected. Contact technical support or service
provider.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ghe80suGhe100ssGhe100suGhe80ssGhe119su

Table of Contents