15. MMA: Machine Setup
1. For DC+ electrodes, connect earth clamp to the
negative (-) dinse connection, and electrode holder to
the positive (+) dinse connection.
DC+ Electrode
Electrode Holder (+)
Earth Clamp (-)
3. Connect the plug into a 10 AMP power point, then
switch the machine ON.
ON
OFF
GAS IN
2. For DC- electrodes, connect earth clamp to the
positive (+) dinse connection, and electrode holder to
the negative (-) dinse connection.
DC- Electrode
Earth Clamp (+)
Electrode Holder (-)
4. Select MMA from the MIG/TIG/MMA selector.