Care and Cleaning
CAUTION
• Before cleaning, be sure to stop the operation and turn off the circuit breaker.
• Do not touch the aluminum fi ns of the indoor unit. If you touch those parts, this may cause an injury.
Quick reference
Cleaning parts
Front panel
• Wipe it with a soft damp cloth.
• Only neutral detergent may be used.
If dirty
Air fi lter
• Vacuum dust or wash the fi lter.
Once every 2 weeks
Indoor unit, outdoor unit
and remote controller
• Wipe them with a soft cloth.
If dirty
Notes on cleaning
For cleaning, do not use any of the following:
• Water hotter than 40.0°C
• Volatile liquid such as benzene, petrol and thinner
• Polishing compounds
• Rough materials such as a scrubbing brush
Page 33
Air quality fi lter (enzyme blue with PM 2.5)
To purchase the fi lters (Table 1) or to purchase the another type, contact the dealer
where you bought the air conditioner.
The method of cleaning and replacement of the fi lters may differ depending on the model.
Refer to the label attached to the separately sold fi lters themselves.
Table 1
Deodorizing filter (enzyme blue) − without frame (set of 2)
Air quality fi lter (enzyme blue with PM 2.5) − without frame (set of 2)
Titanium apatite deodorizing fi lter − without frame (set of 2)
Deodorizing fi lter (enzyme blue), titanium apatite deodorizing fi lter.
• Vacuum dust or replace the fi lter.
[Cleaning]
Once every 6 months
Air quality fi lter (enzyme blue with PM 2.5)
• No cleaning is required. Please replace the fi lter every 6 months.
Item
[Replacement]
Once every 3 years
Page 34
Care
Part No.
BAFP094A41
BAFP094A43
KAF970A46
Page 34