  • Page 18: Instrument Panel

    3.Operation 3.1 Instrument Panel Each display of the operation panel is illustrated as follows. Read and fully understand the explanations and be sure to operate safely: A220161 PRESSURE SELECTOR switch [CONTROL POWER] switch [START] button (PDSF375, PDSG310 only) Switch to change high pressure Start operation by holding Switch to start and stop mode and low pressure mode.
  • Page 30 3.Operation 5. Once the engine has started up, leave it running to warm-up for 5 minutes. The discharge air pressure gauge [B] in this condition ranges from PDS400: 43 to 130PSI / PDSF375: 43 to 174PSI / PDSG310: 43 to 230PSI.
  • Page 31 3.Operation 3.4.2 How to select operating pressure [PDSF375DP, DPC-6E1 PDSG310DP-6E1]  Set the PRESSURE SELECT switch [A] to the [LOW] position for PDSF375: 100PSI / PDSG310: 150PSI and the [HIGH] position for PDSF375: 150PSI / PDSG310: 200PSI. ※You can alternate the usage pressure during operation. A220161 3-14...
  • Page 35 3.Operation 3.4.7 Stopping <Procedure> 1. Close fully service valve. 2. Set the CONTROL POWER switch [A] to position. 3. The engine will stop automatically after a 180 second cool down. 4. After stopping the engine, close and lock the front panel. Store the key in a safe place. A220163 3.4.8 Air bleeding in fuel line Should the machine stop due to fuel shortage, perform air bleeding according to the following steps.
  • Page 47: Emergency Stop

    3.Operation 3.8 Emergency Stop 3.8.1 Emergency stopping procedures  If it is necessary to stop the machine for emergency, press the Emergency Stop button which set up under part of the operation panel. When doing shut down by emergency stop button, the machine will be stopped immediately.
  • Page 56: Periodic Inspection/Maintenance

    5.Periodic inspection/Maintenance 5.3 Periodic Inspection List (Unit:Hour) Maintenance Daily 250 500 1,000 2,000 3,000 6,000 12,000 Page Check compressor oil level. ○ Drain separator receiver tank. ○ Check for looseness in pipe connecting part, 3-10 ○ and wear and tear of pipe. Check oil, water, fuel and air leak.
  • Page 57 5.Periodic inspection/Maintenance ◎Refer to engine operation manual for inspection and maintenance of an engine. For the details, contact our office nearby or distributor. (Unit:Hour) Maintenance Daily 1,000 2,000 3,000 6,000 Page Check engine oil level. ○ Check coolant level. ○ Check fuel ○...
  • Page 74 5.Periodic inspection/Maintenance 5.5.34 Change rubber coupling Every 3 years When replacing it, contact directly us or distributor because it requires expert technical knowledge. 5.5.35 Change oil seal/bearing Every 12,000 hours When replacing it, contact directly us or distributor because it requires expert technical knowledge.
  • Page 83 7.Specifications 7.3 Wiring Diagram PDS400S, SC-6E1 / PDSF375DP,DPC-6E1 / PDSG310DP-6E1 A180195E-2...
  • Page 85: Piping Diagram

    7.Specifications 7.4 Piping Diagram 7.4.1 Compression air・Compressor oil PDS400S-6E1...
  • Page 86 7.Specifications PDSF375DP-6E1 7-10...
  • Page 87 7.Specifications PDSG310DP-6E1 7-11...
  • Page 88 7.Specifications PDS400SC-6E1 (After-cooler type) 7-12...
  • Page 89 7.Specifications PDSF375DPC-6E1 (After-cooler type) 7-13...
  • Page 90 7.Specifications 7.4.2 Fuel Piping A180470E 7-14...
  • Page 93 发行者 总公司 工厂 新泻县燕市下粟生津 3074 TEL 0256-93-5571 FAX 0256-94-7567 (禁止擅自复印以及转载) HOKUETSU INDUSTRIES CO., LTD. 8TH FLOOR SHINJUKU SAN-EI BLDG, 22-2 NISHI-SHINJUKU 1-CHOME,SHINJUKU-KU TOKYO 160-0023 JAPAN TEL:81-3-3348-7281 FAX:81-3-3348-7289 URL:http//www.airman.co.jp Copyright(C)2022 HOKUETSU INDUSTRIES CO., LTD. All Rights Reserved. 39600 25450 Printed AUG.2022...