Advertisement

Smoke cut filter replacement cycle (continued)
Filter Remaining Time
-  -   -
12 to 0 (hours)
Note
z When the remaining time reaches 0, the projector's light output will be limited to 50% or less to protect the
projector. The output limit will be released after the smoke cut filter is replaced with a new one.
z The [FILTER REMAINING TIME] item will only appear in the [STATUS] screen when the projector's [FILTER
TYPE] setting is set to [SPECIAL].

If the indicator lights...

Check the status of the indicator, and perform the following solutions.
■ Status : Lit red
Situation : The filter is clogged
or the environment or inside of the projector is very hot.
Check
Is the smoke cut filter dirty?
Is the air intake/outlet blocked?
Is the projector being used more than
1 400 m (4 593') above sea level?
Note
z We recommend replacing the smoke cut filter within 10 hours of the filter indicator < 过滤网 > lighting.
z Prolonged operation without replacement of the smoke cut filter may reduce the lifespan of parts and result in
malfunctions.
z If the filter indicator < 过滤网 > still lights or flashes, even after doing the above, contact your dealer for repairs.
:
日本福冈县福冈市博多区美野岛四丁目1番62号
:
https://panasonic.cn/
:
©
松下互联株式会社 2022版权所有
Filter clogging has not occurred.
Filter clogging has occurred.
Filter indicator < 过滤网 >