Page 1
1011 460 Operating instructions and spare parts list OptiGun GA03-P Automatic powder gun 0102 II 2D Translation of the original operating instructions...
Page 2
To the best of our knowledge and belief, the information contained in this publication was correct and valid on the date of publication. Gema Switzerland GmbH makes no representations or warranties with respect to the contents or use of this publication, and reserves the right to revise this publication and make changes to its content without prior notice.
Table of contents General safety regulations Safety symbols (pictograms) ................... 3 Proper use ....................... 3 Product-specific safety measures ................4 OptiGun GA03-P automatic powder gun ........... 4 About this manual General information ....................5 Product description Field of application ....................7 Utilization ....................
INFORMATION! Useful tips and other information Proper use 1. The OptiGun GA03-P Automatic powder gun is built to the latest specification and conforms to the recognized technical safety regulations and is designed for the normal application of powder coating.
OptiGun GA03-P automatic powder gun The OptiGun GA03-P Automatic powder gun is a constituent part of the system and is thus integrated into the safety system of the plant. If it is to be used in a manner outside the scope of the safety concept, then corresponding measures must be taken.
General information This operating manual contains all the important information you require for the working with the OptiGun GA03-P Automatic powder gun. It will safely guide you through the start-up process and give you references and tips for the optimal use of your new powder coating system.
V 10/14 Product description Field of application The OptiGun GA03-P Automatic powder gun is built exclusively for the electrostatic coating with organic powders. Any other use is considered non-compliant. The manufacturer shall not be liable for damage resulting from such use; the user bears sole responsibility for such actions.
Processible powders OptiGun GA03-P Plastic powder Metallic powder Enamel powder WARNING: The OptiGun GA03-P Automatic powder gun may only be connected to the following control units: OptiStar CG12-CP and OptiStar CG11-P (with Trigger adapter only)! 8 • Product description OptiGun GA03-P...
Shaft with removable high voltage cascade SuperCorona ring Scope of delivery OptiGun GA03-P Automatic powder gun with gun cable (20 m)*, negative polarity Electrode rinsing air hose (20 m)* Flat jet nozzle NF27, complete (incl. electrode holder) Cable tie with Velcro closure...
V 10/14 SuperCorona ring Field of application The SuperCorona is an optional extension for the OptiGun GA03-P Automatic powder gun, allowing for a better surface quality when coating with the powder coating equipment. When coating wheel rims, drawers, radiators, lamps etc. the surface quality is exceptional, also in places with higher coating layer requirements.
Page 13
V 10/14 SuperCorona assembly Before fitting the SuperCorona ring, make sure that the connection and the plug-in connector are free from grease and powder, otherwise the electric contact cannot be guaranteed. CLICK Product description • 11 OptiGun GA03-P...
(see the operating manual of the gun control unit). The functions of the spray nozzles are described in the following sections. 12 • Product description OptiGun GA03-P...
Since powder can accumulate on the baffle plate, it must be rinsed with compressed air. The electrode rinsing air cleaning ability depends on the powder and its sintering ability. The electrode rinsing air adjustment on the gun control unit is described in the corresponding operating manual. Product description • 13 OptiGun GA03-P...
Few wearing parts (nozzle and SuperCorona) Easily removable cascade because free of grease, with integrated current limiting resistors Connection for SuperCorona Ring Quick and simple connection and disconnection of SuperCorona ring 14 • Product description OptiGun GA03-P...
V 10/14 Commissioning Preparation for start-up Basic conditions When starting up the OptiGun GA03-P Automatic powder gun, the following general conditions impacting the coating results must be taken into consideration: Gun correctly connected Gun control unit correctly connected Corresponding power and compressed air supply available...
Page 18
V 10/14 5,5 bar 6,0 bar 6,5 bar OptiGun GA03-P Automatic powder gun – Connection instructions - overview Electrode rinsing air Transport air hose hose Powder hose Control signal cable Gun cable Dense phase pump Pinch valve air Powder hopper...
If a malfunction occurs, see the troubleshooting guide, as well as the gun control unit operating manual! NOTE: The further start-up procedure for the OptiGun GA03-P Automatic gun is explicitly described in the OptiStar CG12-CP/CG11-P Gun control unit operating instructions (chapter "Initial start-up" and "Daily start-up")!
The adjusted value of the total air volume can be left as it is, as long as the same diameter powder hose is used. If the hose diameter changes, the total air volume must be reset! 18 • Initial start-up OptiGun GA03-P...
3. Unscrew the threaded sleeve approx. 45°, so that the flat jet nozzle (or its extension) can be moved slightly 4. Turn the flat jet nozzle to desired axis direction 5. Tighten the threaded sleeve firmly again Initial start-up • 19 OptiGun GA03-P...
3. Switch on the gun control unit 4. Adjust the coating parameters or select one of the programs. Check by observing the LED displays 5. The workpieces can be coated now 20 • Initial start-up OptiGun GA03-P...
1. Switch off the powder gun control unit. The adjustments for high voltage, powder output volume and electrode rinsing air remain stored. 2. If working interruptions take place, such as lunch time, night time etc. disconnect the main compressed air supply Initial start-up • 21 OptiGun GA03-P...
General information NOTE: Regular, careful cleaning and maintenance extends the service life of the OptiGun GA03-P Automatic powder gun and ensures long- lasting, uniform coating quality! ► The parts, which are to be replaced during maintenance work, are available as spare parts. These parts will be found in the...
Nozzles with deflectors: if the wedge of the electrode holder is worn down, then the electrode holder is to be replaced 24 • Cleaning and maintenance OptiGun GA03-P...
V 10/14 Maintenance The OptiGun GA03-P is designed to require only a minimum amount of maintenance. 1. Clean gun with dry cloth, see chapter "Maintenance" 2. Check connection points to powder house. 3. Replace the powder hoses, if necessary. Replacing parts Except for the replacement of possible defective parts, there are very few repairs to be made.
The cascade can be replaced trouble-free. The repair of the gun cable connection, however, may only be made by an authorized Gema Service center. Contact your Gema representative for details! Cleaning and maintenance • 31 OptiGun GA03-P...
Fault Causes Corrective action Gun not connected Connect the gun H11 (Help code on control unit) Gun plug or gun cable Contact local Gema defective representative Remote control on Contact local Gema powder gun defective representative Compressed air not Connect the equipment...
Page 36
Fluidizing tube in the gun Replace clogged Filter elements in the Replace Application pump worn Fluidization not running see above NOTE: Additional error descriptions are to be found also in the control unit operating instructions! 34 • Fault localization OptiGun GA03-P...
When using the spare parts from other manufacturers the explosion protection is no longer guaranteed. If any damage is caused by this use all guarantee claims become invalid! ► Only original Gema spare parts should be used. Spare parts list • 35 OptiGun GA03-P...
► If the powder gun cable (4) is defective, it is to be completely sent in for repair! OptiGun GA03-P Automatic powder gun – complete, polarity negative, incl. pos. 1-9 1010 200 OptiGun GA03-P Automatic powder gun – complete, polarity positive, incl. pos. 1-9 1010 201 Powder gun body OptiGun GA03-P –...
1008 664 Cylinder screw – M4x6 mm 1008 639 O-ring – Ø 9.5x1.5 mm 1008 665 O-ring – Ø 8.5x1 mm 1008 666 Pin allocation white green Bridge brown Shield Gun cable (complete) 42 • Spare parts list OptiGun GA03-P...
V 10/14 OptiGun GA03-P round jet nozzles – overview (wearing parts) Field of A + B Threaded sleeve Deflectors application Suitable for large NS04 Ø 16 mm 331 341 surfaces 1008 150 Ø 24 mm 331 333 1008 152 1008 151 Ø...
V 10/14 OptiGun GA03-P gun extensions Gun extensions L = 150 mm L = 300 mm without nozzle 1008 616 1008 617 without nozzle 1007 718 1007 719 with Flat jet nozzle NF25 1007 747 1007 746 with Round jet nozzle...
Page 50
V 10/14 OptiGun GA03-P spray nozzles for extensions – overview (wearing parts) 1007 718 1007 719 Field of A + B Threaded sleeve Deflectors application NF25 Profiles/flat parts 1007 743 1007 735 NF25 1007 684 NF26 Complex profiles and depressions...
Need help?
Do you have a question about the OptiGun GA03-P and is the answer not in the manual?
Questions and answers