INSTALLATION MANUAL
To Qualifi ed Installer in Installation Work and Service
Air purifi er kit
(For 4-Way cassette type)
Model: TCB-EAPC1UHP-E
Observe the safety precautions described in the Operation Manual of the
Air purifi er kit, Installation Manual of the 4-way cassette type air conditioner
(indoor unit), or the Installation Manual supplied with the ceiling panel.
COMPONENTS
Part Name
Main frame
Dust collector
Deodorize fi lter
Wireless receiver
and Dust sensor
Remote controller
Remote controller holder
INSTALLATION DIAGRAM OF AIR PURIFIER KIT
Q'ty
Part Name
Battery
Actuator
1
Flat head wood screw
(Ø3.1×16L [mm])
Earth screw
1
Screw
(Ø4×10L [mm])
Screw
2
(Ø3×8L [mm])
Cord clamp
(Ø5.9 mm)
1
Cord clamp
(Ø4.4 mm)
Operation Manual
1
Installation Manual
(This Manual)
1
CD-ROM
Indoor unit
Ionizer brush
(Assembled into the Main frame)
Main frame
Deodorize fi lter
(Attach to the Main frame)
Wireless receiver unit
Ceiling panel
Dust collector
Actuator
(Install on the Air fi lter)
Air fi lter
Air inlet grille
• Thank you for purchasing Air purifi er kit for TOSHIBA air conditioners.
• Read this manual carefully for correct installation of the Air purifi er kit
before starting work.
• After the installation is completed, execute a test run to check for
normal operation and explain how to use and maintain the Air purifi er
kit to the customer according to the Operation Manual.
Ask the customer to keep this manual with the Operation Manual.
PREPARATION
Indoor unit preparation
To make screw holes of indoor unit are empty for the installation of the Air purifi er
kit.
So, some parts and current screws need to be disassembled.
Q'ty
2
CAUTION
• Be sure to stop operation of the air conditioner before work and then turn off
1
switch of the breaker.
• Wear heavy work gloves during the installation work to avoid injury.
2
1
1.
Remove the fan guard or cover sensor from indoor unit (depended on each
model) follow position as below.
7
• In case remove the fan guard
2
1
1
1
1
Fan guard
1
• In case remove the cover sensor
2.
Remove screw that fi xed the bell mouth with indoor unit 1 pc. as position
below.
Note:
• After remove this screw, please keep it for fi x the Air purifi er kit with indoor unit
for this position.
- 1 -
Fan guard
Screw 4 pcs.
Cover sensor
Cover sensor
Screw 1 pc.
Indoor unit
Bell mouth
Remove Screw 1 pc.
Indoor unit
Indoor unit
1-EN