12.3. Adjustment Standard (Base Unit)

When connecting the simulator equipment for checking, please refer to below.
12.3.1. Bottom View
Spectrum Analyzer
DC
5.5V
Spectrum Analyzer
STM/CKM/P15
Frequency Counter (*1)
Send command "SFR", then
the frequency output on this TP.
Oscilloscope (*2)
Start Monitor
Note:
(*1) is referred to No.2 of Check Check Table for RF part (P.43)
(*2) is referred to Power Supply Circuit/Reset Circuit (P.14)
PC
UART
JIG
GND
UTX
URX
C552
UTX URX
C521
DC
GND
ANT2_TP
GRY
C301
ANT_C3
PUR
DCM
F301
3.0A
+5.5V
TP_ANT_BT
R751
Q652
Q653
IC611
L661
C663
C662
R611
C664
C611
C602
R606
R613
R601
RSTN
R312
R602
C809
Q601
C515
Q302
IC601
C312
IC502
VDD2
VDD4
R511
C601
R507
C518
R672
C505
R311
STM/CKM/P15
VDD5
C501
R517
VDD1
R515
Q301
R516
VDD3
MIN MIP
C455
C479
C454
C476
60
Oscilloscope
C721
Q732
R733
ANT1_TP
Q731
C731
R735
R736
L1R
R721
L1T
C115
SPN
Q155
R156
SPP
C514
R162
Q161
R166
C184
C171
C108
TP9
C181
C173
R107
TP10
C111
R112
R151
R111
C107
C351
CHARGE+
CHARGE-
CHG
BRN
TEL
YLW
ORG
Volt
SP
Meter
BLU
Oscilloscope
A
Audio Frequency
MIC
OSC