Category 5 Cable; Category 5 Cable Specifications; Table C-1. Electrical Requirements Of Category 5 Cable - NETGEAR GS504T Installation Manual

4 port 100/1000mbps copper gigabit switch
Hide thumbs Also See for GS504T:
Table of Contents

Advertisement

GS504T.Manual.FINAL
6/2/00

Category 5 Cable

Category 5 distributed cable that meets ANSI/EIA/TIA-568-A building wiring
standards can be a maximum of 328 feet (ft) or 100 meters (m) in length, divided
as follows:
• 20 ft (6 m) between the hub or switch and the patch panel (if used)
• 295 ft (90 m) from the wiring closet to the wall outlet
• 10 ft (3 m) from the wall outlet to the desktop device
The patch panel and other connecting hardware must meet the requirements for
100 Mbps operation (Category 5). Only 0.5 inch (1.5 cm) of untwist in the wire pair
is allowed at any termination point.

Category 5 Cable Specifications

Ensure that the fiber cable is crossed over to guarantee link.
Table C-1 lists the electrical requirements of Category 5 UTP cable.

Table C-1. Electrical Requirements of Category 5 Cable

Specification
Number of pairs
Impedance
Mutual capacitance at 1 KHz
Maximum attenuation (dB per 100 m, at 20° C)
NEXT loss (dB minimum)
cabling guidelines
12:49 PM
Page 26
C-2
Category 5 Cable Requirements
Four
100
± 15%
5.6 nF per 100 m
at 4 MHz: 8.2
at 31 MHz: 11.7
at 100 MHz: 22.0
at 16 MHz: 44
at 31 MHz: 39
at 100 MHz: 32