HOLLISTER-WHITNEY Rope Gripper 620 Installation, Maintenance & Troubleshooting Manual page 29

Pumping unit
Table of Contents

Advertisement

Commonly Asked Questions:
Wiring from the gripper to pump unit is color coded per Chart 2.
Connect terminals RG1and RG2 to elevator control Power Wires
Connect terminals RG5 and RG7 to elevator control Safety String.
Check control diagram for proper connection.
GRIPPER WILL NOT RESET - GRIPPER SET ON ROPES
o Check location of rotating shaft in cam; if rotating shaft tube is
against wear-out switch refer to section concerning Lining
Replacement
o Check for open Safety circuit.
o Check for blown fuse; refer to that section
"ROPE GRIPPER
" Hydraulic Oil
®
Check level with the "ROPE GRIPPER
the Oil Level Window on the Oil Reservoir.
Use SHC524 Mobil 1 Synthetic Hydraulic Oil or Mobil 1 Fully Synthetic ATF
(Automatic Transmission Fluid) to top off oil level.
WIRE ROPE LUBRICATION
Use a high friction lubricant such as: NYLUBE CABLE CARE #65 or AMERICAN OIL
VITALIFE #600. Care should be taken not to over lubricate
Complete Trouble Shooting Guide begins Page 17
" in the loaded position, the level should fully cover
®
White
RG2
Black
RG3
Red
RG4
Orange
RG5
Blue
RG6
Green
Ground
Pigtail to Pumping
Unit Wiring
CHART 2
DIAGRAM 4
BULLETIN 1144
Page 29 of 29
11/12/19