5

Removing the Transport Protection of the Glass Condenser

When installing the glass condenser and the glass fittings, pay special attention due to danger of glass breakage.
The glass condenser and the glass fittings are placed beneath the hood of the Distiller. In order to be able to remove the
hood, two each quick-release catches on each side of the unit as well as two hidden screws (see photo below) between the
hood and the basic housing need to be loosened.
Before initiation, remove the transport protection (bubble wrap and rigid foam parts) around the glass condenser, clear all
connection openings that are covered by adhesive tape or plastic film and carefully empty the sand from the condenser.
Rinse the condenser with clear water and re-assemble as shown below. Place the cone of the glass condenser into the
plastic ring on the right-hand side boiler. The bi-distillate outlet must point to the front. Place the round felt washer on top
of the glass condenser; it will prevent dislodging of the holding clamp which is connected with the unit through the four
holding arms ③. Fit together those hose couplings ② having the same colour.
6

Operating Voltage

The Distillation Apparatus must be connected to the mains supply through a correctly installed, on-site
main switch, or, permanently connected, through a CEE plug in conformity with IEC standard 60309-
2. The unit is a protection class I electrical appliance, a connection to the protective earth is to be en-
sured. For information on the value of the required mains fuse see Technical Data, chapter 12, of these
instructions.
The electrical connection must ensure an all-pole separation from the mains at any time. Shock-proof
sockets or main switches to separate the Distillation Apparatus from the mains must be installed in such
a way as to ensure clear identifiability and easy accessibility at any time.
The mains connection cable must not touch any hot surfaces of the unit. It may not lead underneath
the unit. The main switch of the Distillation Apparatus must be off (position O). The voltage on the
nameplate (at the left-hand side of the unit) must be identical to the mains voltage. If they are identical,
connect the unit to the mains.
Please also refer to chapter 15 of these operating instructions "Connection to the Mains"..
09/2020
Place the hood back onto the unit and secure with the two
screws and four quick-release catches. Then install the glass
fittings. Screw together the glass valve with the mono-
distillate outlet (left-hand front of the unit), and the outlet
tube with the bi-distillate outlet.