Summary of Contents for Flight Light L860

  • Page 1 L860 Elevated LED Perimeter Light with LED Flood Light Revision D 8/20/2021 MWI-05-041 Flight Light Inc. 2708 47 Avenue Sacramento, CA 95822 www.flightlight.com Ph: 916-394-2800...
  • Page 2: Table Of Contents

    HL-860F LED Perimeter Light with LED Flood Light User Instructions Your Flight Light HL-860FL light fixture has been designed to provide years of service, please follow the recommendations outlined in this guide. Contents A. Safety Measures ....................2 B. Installation ....................... 3 1.
  • Page 3: Safety Measures

    A. Safety Measures You must know whether your heliport lighting system is powered by AC or DC before installing the fixture. AC models work on either 120VAC or 240VAC if Halogen or on a range of 100 to 240VAC if LED. DC models operate from 10 to 30VDC. The lights are designed to be installed in a parallel circuit, which maintains a constant voltage and brightness for all lights.
  • Page 4: Installation

    B. Installation Each light is packed in its own box 18” x 12” x 12”. Carefully remove the light from its box and inspect for damages. If any damages are found, file a claim with the carrier. 1. The perimeter light and the flood light are usually wired together in parallel inside the light fixture so they will both turn ON when power is applied.
  • Page 5: Base Can Installation

    1. Base Can Installation There is no standard way to build a helipad. Each project includes its own individual variables. Some of these are: • The type of paving material to use • Anticipated loads and traffic • The kind of subsoil •...
  • Page 6: For Existing Pavements

    For Existing Pavements: 2. To install base cans, begin by core drilling (typically 12"-14” diameter, the depth will be per the terrain and/or suggestion of the civil engineer/contractor) holes in the locations specified by the project engineer. Saw cuts should then be made to allow room for the fixture power cables (typically 3"...
  • Page 7 In this case, consult with your project engineer before proceeding. 10. FAILING TO HAVE PROPER DRAINAGE WILL DAMAGE THE LIGHT. FLIGHT LIGHT INC WILL NOT COVER SUCH WATER DAMAGES UNDER WARRANTY. 11. Once satisfied with drainage system, move on to the installation of the fixture power cables.
  • Page 8 Notes: 1. Drain rock shall be graded from 1 inch to ¼ inch. 2. Drain rock shall be encased in a filter fabric material to avoid soil infiltration into the drain rock. 3. Recommended depth of drain rock unit varies dependent upon the type of existing soils. a.
  • Page 9: For New Installations

    For new installations: For a completely new helipad, before pouring the concrete, create the appropriate drainage system. See Figure 1 on page 7 and notes. 1. Install the rubber grommets in each of the side holes. 2. Install the base can drain fittings provided (pictured below) into each base can drain hole.
  • Page 10 In this case, consult with your project engineer before proceeding. FAILING TO HAVE PROPER DRAINAGE WILL DAMAGE THE LIGHT. FLIGHT LIGHT INC WILL NOT COVER SUCH WATER DAMAGES UNDER WARRANTY. 5. Once satisfied with drainage system, move on to the installation of the fixture power cables.
  • Page 11: Soil- Stake Installation

    2. Soil- Stake Installation L895 Mounting Stake galvanized to ASTM-A123/A123M-02 Shipped with: 1 x 2 hole cable clamp and 2 x #10-24 x 1 ¾” SS machine screws 1. Thread the coupling of the light into the mounting stake and run fixture power cables to each light, one black wire, one white wire, and one green wire (grounding) to each can.
  • Page 12: Wiring

    C. Wiring The installation of lights is recommended to be done in a parallel circuit in a secure, waterproof junction box. Junction boxes are not provided with the lights. The gauge of the electrical wire is to be calculated by the electrical engineer and should be sufficient to handle the rated current and voltage demand.
  • Page 13: 135Vac

    1. 90-135VAC WARNING! Do not look at Infrared Light Fixtures while they are ON! Infrared light output is hazardous to your eye Revision D – August 20th, 2021 Page 12...
  • Page 14: 8-277Vac

    2. 208-277VAC 208-277VAC Revision D – August 20th, 2021 Page 13...
  • Page 15: 30 Vdc

    3. 10-30 VDC Revision D – August 20th, 2021 Page 14...
  • Page 16: 30 Vdc + Dimming

    4. 10-30 VDC + DIMMING Note: Only the HL-860 LED perimeter light dims, the LED flood light does not dim. Revision D – August 20th, 2021 Page 15...
  • Page 17: Limited Warranty

    LED Light Fixture, for a period of 5 years from the date of shipment to Buyer. Buyer’s Remedies: If any such goods are found to be materially defective within the warranty period, Flight Light Inc. agrees to attempt to repair, and if unable to repair, to replace the defective goods without charge to Buyer.