ipf electronic OY36 Quick Instruction Manual

Safety light curtain
Hide thumbs Also See for OY36:

Advertisement

Quick Instruction Manual Safety Light Curtain OY36
Devices for bodyprotection
Safety Information
The following points must be observed for a correct and safe use of the OY36 safety device:
• The stopping system of the machine must be electrically controlled.
• This control system must be able to stop the dangerous movement of the machine within the
total machine stopping time T as per paragraph 1.3.3 of the manual included in the CD supplied
and during all working cycle phases.
• Mounting and connection of the safety light curtain must be carried out by qualified personnel
only, according to the indications included in the special sections (refer to sections 2; 3; 4; 5) and
in respect to the applicable standards.
• The safety light curtain must be securely placed in a particular position so that access to the
dangerous zone is not possible without the interruption of the beams.
• The personnel operating in the dangerous area must be well trained and must have adequate
knowledge of all the operating procedures of the safety light curtain.
• The TEST button must be located outside the protected area because the operator must check
the protected area during all Test operation.
• The RESET/RESTART button must be located outside the protected area because the operator
must check the protected area during all Reset/Restart operations.
• Please carefully read the instructions for the correct functioning before powering the light
curtain.
Precautions to be observed for the choice and installation
Make sure that the protection level assured by the OY36 device (Type 4) is compatible with the real
danger level of the machine to be controlled, according to EN 954-1 and EN 13849-1.
The outputs (OSSD) of the ESPE must be used as machine stopping devices and not as command
devices. The machine must have its own START command.
The dimension of the smallest object to be detected must be larger than the resolution level of
the device.
The ESPE must be installed in a room complying with the technical characteristics indicated in
section 10 "Technical Data" of the manual include in the CD supplied.
Do not install device near strong and/or flashing light sources or close to similar devices.
ipf electronic gmbh
• Rosmarter Allee 14 • 58762 Altena
Tel +49 2351 9365-0 • Fax +49 2351 9365-19
Short-Manual • Subject to alteration! Stand: December 2022
info@ipf-electronic.com • www.ipf-electronic.com
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OY36 and is the answer not in the manual?

Questions and answers

Summary of Contents for ipf electronic OY36

  • Page 1 Precautions to be observed for the choice and installation Make sure that the protection level assured by the OY36 device (Type 4) is compatible with the real danger level of the machine to be controlled, according to EN 954-1 and EN 13849-1.
  • Page 2: Receiver (Rx)

    • The presence of intense electromagnetic disturbances could jeopardise device functioning. This condition shall be carefully assessed by seeking the advice of ipf electronic Technical service. • The operating distance of the device can be reduced in presence of smog, fog or airborne dust.
  • Page 3: Alignment Procedure

    LED turns OFF and the red LED turns ON (condition where an object has been detected, SAFE). ipf electronic gmbh • Rosmarter Allee 14 • 58762 Altena │...
  • Page 4: Diagnostic Functions

    TEST/START button to reset the device consequently to an object interception. This occurs only when the device runs under the manual Reset mode. ipf electronic gmbh • Rosmarter Allee 14 • 58762 Altena │ Tel +49 2351 9365-0 • Fax +49 2351 9365-19 │...
  • Page 5: Receiving Unit

    - Main microprocessor failure ipf electronic gmbh • Rosmarter Allee 14 • 58762 Altena │ Tel +49 2351 9365-0 • Fax +49 2351 9365-19 │ info@ipf-electronic.com • www.ipf-electronic.com...
  • Page 6 - Power supply voltage is ON green outside allowed - Switch OFF and switch ON the device; range if the failure continues, please contact ipf electronic. - Main microprocessor failure ipf electronic gmbh • Rosmarter Allee 14 • 58762 Altena │...

Table of Contents