Owner’s Manual 4” Submersible Pumps Two & Three Wire, 1/2 through 1-1/2 HP 2Wire Models EFSUB5-102-1 EFSUB5-102 EFSUB7-102 EFSUB10-102 3 Wire Models EFSUB5-103 EFSUB7-103 EFSUB10-103 EFSUB15-103 EFSUB10-203 EFSUB15-203 TABLE OF CONTENTS Pump Selection ....2-3 General Safety .
Page 2
NOTE, your pump needs to be installed at minimum 5’ above the bottom of the well and 15-20’ below the surface of the water column in the well. For parts or assistance, call ECO-FLO Customer Service at 1-877-326-3561...
• The correct HP for the depth the pump will be in the well. • The correct GPM (gallons per minute) for your application. • The correct voltage • The correct number of wires • The correct control box (if applicable) For parts or assistance, call ECO-FLO Customer Service at 1-877-326-3561...
Can shock, burn or cause death. To avoid dangerous or fatal HAZARDOUS VOLTAGE electric shock hazard, use pump only in a water well. For parts or assistance, call ECO-FLO Customer Service at 1-877-326-3561...
NOTICE: See installation Wiring Diagrams for typical wiring hookups and submersible motor control identification. For parts or assistance, call ECO-FLO Customer Service at 1-877-326-3561 For parts or assistance, call ECO-FLO Customer Service at 1-877-326-3561...
Page 6
Three Wire- 1/2 through 2 HP Submersible Motor Control. and one ground wire. Submersible motor control is not Follow color coding when connecting submersible required.) motor control. (Yellow to Y, Red to R, Black to B) For parts or assistance, call ECO-FLO Customer Service at 1-877-326-3561...
To avoid dropping pump down well or damaging wires or heat). splices, NEVER allow pump wires to support weight of NOTICE: Keep torch moving. Too much concentrated pump. heat may damage tubing. For parts or assistance, call ECO-FLO Customer Service at 1-877-326-3561...
Page 8
(Fig. 4). adjust as needed. 10. Install sanitary well seal or pitless adapter unit, well unit, electrical conduit and surface piping. Installation must meet all code requirements that apply. For parts or assistance, call ECO-FLO Customer Service at 1-877-326-3561...
Page 9
This conductor must be at least as large B. Clamp or weld (or both if necessary) this bonding as the circuit conductors supplying the pump SAVE THESE INSTRUCTIONS. conductor to the grounding means provided with the For parts or assistance, call ECO-FLO Customer Service at 1-877-326-3561...
AVC if necessary. Replace pipe above that point. Measure distance from pressure switch to Move switch to within 1’ (.3M) of tank. Pressure switch too far from tank. tank. For parts or assistance, call ECO-FLO Customer Service at 1-877-326-3561...
Page 11
If necessary, separate gas from air before it enters pressure tank. Air volume control not working Make sure ports and ball check valves are Replace control if necessary (standard tanks only). clear. For parts or assistance, call ECO-FLO Customer Service at 1-877-326-3561...
EFSUB0506 3/4HP 10GPM EFSUB0753 1HP 10GPM EFSUB1003 1HP 20GPM EFSUB1004 1.5HP 10GPM EFSUB1503 1.5HP 20GPM EFSUB1504 Suction Screen EFSUB0509 For parts or assistance, call ECO-FLO Customer Service at 1-877-326-3561 For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561...
WARRANTY Retain Original Purchase Receipt for Warranty Eligibility Limited Warranty Manufacturer warrants to the original consumer purchaser (“Purchaser” or “You”) that its products are free from defects in material and workmanship for a period of three years from the date of the original consumer purchase. If, within three years from the original consumer purchase, any such product shall prove to be defective, it shall be repaired or replaced at manufacturer’s option, subject to the terms and conditions set forth herein.
Page 14
Manuel des propriétaires 4”Pomes Submersibles TDeux & Trois fil,1/2à travers 1-1/2HP 2Wire Models EFSUB5-102-1 EFSUB5-102 EFSUB7-102 EFSUB10-102 3 Wire Models EFSUB5-103 EFSUB7-103 EFSUB10-103 EFSUB15-103 EFSUB10-203 EFSUB15-203 CONTENTS DU TABLEAU Sélection de la pompe ... . . 16 Sécurité...
Page 15
NOTE, votre pompe a besoin d’être installée 5’au-dessus du fond du puits et 15-20’ au-dessous de la surface de la colonne d’eau dans le puits. Pour les parts ou l’aid, téléphonez au Service de clientele de ECO-FLO 1-877 326-3561...
Page 16
• GPM (gallons par minute) corrects pour les puits. • Le voltage correct • Le numéro correct des fils • Le boîtier de commande correct (si c’est applicable ) Pour les parts ou l’aid, téléphonez au Service de clientele de ECO-FLO 1-877 326-3561...
Page 17
Permettre la pompe ou des composants du système de geler, la garantie sera annulée. pompes thermoplastique Pour les parts ou l’aid, téléphonez au Service de clientele de ECO-FLO 1-877 326-3561...
Page 18
NOTICE: Voyez les Schémas de câblage d’installation pour les raccordements de câblage typiques et le moteur submersible contrôle l’identification. Pour les parts ou l’aid, téléphonez au Service de clientele de ECO-FLO 1-877 326-3561 For parts or assistance, call ECO-FLO Customer Service at 1-877-326-3561...
Page 19
Suivez le codage de couleur lors de la connexion de submersible n’est pas demandée. contrôle du moteur submersible. (Jaune pour Y, Rouge pour R, Noir pour B) Pour les parts ou l’aid, téléphonez au Service de clientele de ECO-FLO 1-877 326-3561...
Page 20
NOTICE: Restez la torche mobile. Trop de chaleur concentrée endommager les fils ou les épissures, Ne permettez jamais les fils peut endommager le tube. de la pompe de supporter le poids de la pompe. For parts or assistance, call ECO-FLO Customer Service at 1-877-326-3561...
Need help?
Do you have a question about the EFSUB5-102-1 and is the answer not in the manual?