3.3. AC Input configuration

The AC input needs to be configured for 115 or 230V use. This is done by connecting male spade terminals using the black
jumper wires (included). These terminals are located above the AC input connector.
Connect
AC input
jumper cable
voltage
between
J17 and J20
115V
J4 and J7
230V
J4 and J20

3.4. AC output configuration

The AC output needs to be configured for 115 or 230V use. This is done by connecting male spade terminals using the black
jumper wires (included). These terminals are located above the AC output connector.