XdA PLACEMENT
The XdA is designed to be placed on a shelf or table. It should never be placed on a carpeted surface
as this will affect the airflow coming into the unit on the bottom side. The feet should never be removed
from the bottom of the unit. The XdA can be rack mounted with the aid of a rack pan or tray. At this
time we do not have a rack ear option available for it.
Before making any connections, make sure that all devices in the system are turned off. Connect the
output of your mixer, preamplifier or soundcard to either the RCA or XLR inputs. The inputs are wired
in parallel, so only one set of inputs should have patch cords connected to them at a time. The XLR
inputs are wired as shown below.
Inputs
The XdA utilizes a switching power supply that automatically senses the incoming AC line voltage and
adjusts accordingly. The range of AC voltages it can be used with is from 90-260VAC. There are no
external fuses or switches that need to be changed when moving the unit from one country to
another.
A grounded power cord must always be used with the XdA. Never lift or break the ground connection.
If your system installation has hum problems, fix the ground loop the proper way at the signal level
connections. Excellent information on these problems and how to fix them are available at the Jensen
Transformer's website, www.jensentransformers.com, under the white paper section.