Page 1
This document and the information contained herein is CONFIDENTIAL to TWINE Solutions Ltd, and shall not be used, published, disclosed, or disseminated outside TWINE in whole or in part without TWINE’s consent. This document contains TWINE trade secrets. Reverse engineering based on any of the information in this document is prohibited.
About This Guide About This Guide The information and requirements provided in this document ensure proper installation and operation of the Twine TS-1800 Digital Thread & Yarn Dyeing system. The customer is responsible for: Preparing the site as described in this document.
Physical Description Physical Description Overview The TS-1800 comprises a single stand-alone unit, as shown in the figure below. Figure 1: TS-1800 Digital Thread & Yarn Dying System Confidential TS-1800 Site Preparation Guide Page 6 Hatnufa 7, Kiryat Arie, Petach Tiqva, 4951025, Israel...
Shipping and Delivery Shipping and Delivery Shipping Pallet The approximate size and weight of the TS-1800 system when mounted on a pallet is as follows: Length (L) 2.25 meters (89 inches) Width (W) 0.89 meters (35 inches) Height (H) 1.74 meters (69 inches) ...
Installation Area General IMPORTANT! If the TS-1800 is going to be located in an area that is not on ground floor level, you must ensure that the area has sufficient capacity for the weight and physical dimensions of the machine.
Installation Area Floor Plan A sample floor plan is shown below, with the TS-1800 placed in a likely operating area. The dimensions shown in the figure are minimum clearance requirements. Figure 3: Floor Plan Sample (not to scale) Confidential TS-1800 Site Preparation Guide...
The customer is responsible for ensuring that all tasks described in this section are performed by qualified personnel. Power A stable, reliable source of power is necessary. Power to the TS-1800 is supplied via a standard wall socket. TS-1800 Power Rating Total power consumption is 3KW.
Network Network Network Connections The TS-1800 should be placed in an area with access to a strong Wi-Fi signal and connected to the network via a LAN communication connection. Min. Internet Speed 40mb Wi-Fi frequency should be 2.4GHz ...
Environmental Conditions Environmental Conditions Temperature, Humidity and Altitude The environmental conditions for the TS-1800 must be maintained within the limits detailed in the table below. Parameter Specification Operating temperature 10°C to 30°C (50°F to 86°F) Non-operating temperature 5°C and 50°C (41°F and 122°F)
Wi-Fi connection Color Selection tools To dye a new color, the TS-1800 must receive a color input in the L*a*b* format This color format can be extracted from a fabric/yarn sample using a spectrophotometer. Examples for recommended spectrophotometers:...
Page 16
Standard Observer: CIE 1964 10 IMPORTANT! It is mandatory to have a spectrophotometer in hand for the installation. Please notify Twine in advance if you do not have one for the training. Confidential TS-1800 Site Preparation Guide Page 16 Hatnufa 7, Kiryat Arie, Petach Tiqva, 4951025, Israel P.O.
Ink cartridges can be used only until the expiration date specified on the cartridge. 10.2 Handling Waste All waste created by the TS-1800 is considered hazardous chemical waste and must be disposed of responsibly. There are 3 types of waste: Empty TDI ink cartridges 2.
Customer Information Customer Information Please fill in the information requested below and send it to your Twine representative. When your Twine representative approves your checklist, he will schedule the system installation. If you have any additional questions, please contact your Twine representative.
Need help?
Do you have a question about the TS-1800 and is the answer not in the manual?
Questions and answers