LAWO Power Core User Manual page 124

Hide thumbs Also See for Power Core:
Table of Contents

Advertisement

10.4.3 VCA Parameters
1.
Select the VCA Group you wish to edit (from the "Source" branch of the 'Tree Definition') and open the
Parm tab to adjust its main parameters.
These are a subset of the
must be unique (e.g. VCA 1), and the VCA Group No (described below).
Use the Display name and Source Color options to define the label and color coding of the VCA master.
The VCA Group No can be used to define a fixed order for the VCA groups 1 to 8. It affects how the groups
appear in the VCA menu; how they are stored in snapshots; and what happens if changes are made to the
configuration.
To maintain compatibility with older ON-AIR Designer projects (< 6.6.0.24), the default setting is "Auto".
However, it is recommended to use a specific number, so that if a VCA Group is later added or deleted, this will
have no affect on the existing groups.
To define a fixed order, you must assign a unique number to every VCA Group source. Alternatively, the option
can be left at "Auto" (to order the VCA Group sources automatically).
Please note:
·
Each VCA Group No. must be used only once within the same configuration.
·
You must not mix the "Auto" and fixed group numbers within the same configuration.
In snapshots, all settings are stored according to the VCA Group No. Thus, if you change from "Auto" to
fixed numbering and wish to use existing snapshots, it is important that the fixed numbering matches that of
the automatic sequence.
124/539
Source parameters
described earlier. Most important is the Source name which
Version: 6.6.0/3