84VP5/84VM5 Installation Guide
(also a reference for optional Quad Mount used with 42VM5 or 42VP5)
ACK
3FH
60H
80H
3FH
06. PICTURE MODE Select
Function
The external control equipment sets the picture mode of the plasma monitor.
Transmission Data
DFH 80H
60H
0AH
DATA00: 01H : NORMAL
02H : THEATER1(It cannot choose in the still picture input of a personal computer.)
03H : THEATER2(It cannot choose in the still picture input of a personal computer.)
04H : Default
ACK
7FH
60H
80H
0AH 01H
DATA00: 01H : NORMAL
02H : THEATER1
03H : THEATER2
04H : Default
07.SCREEN MODE Select
Function
The external control equipment switches the screen mode of the plasma monitor.
Transmission Data
DFH 80H
60H
51H
DATA00 02H : STADIUM
03H : ZOOM
04H : NORMAL
05H : FULL
06H : REAL
08H : UNDERSCAN
09H : 14:9
ACK
7FH
60H
80H
51H
DATA00 02H : STADIUM
03H : ZOOM
04H : NORMAL
05H : FULL
06H : REAL
08H : UNDERSCAN
09H : 14:9
08. AUTO PICTURE Select
Function
The external control equipment switches on or off the AUTO PICTURE of the plasma monitor.
Transmission Data
DFH 80H
60H
7FH
DATA00 : USER PICTURE Gain Flag
DATA01 : AUTO PICTURE Select Flag 09H
DATA02 00H : ON
01H : OFF
ACK
7FH
60H
80H
7FH
DATA00 : USER PICTURE Gain Flag
DATA01 : AUTO PICTURE Select Flag 09H
DATA02 00H : ON
01H : OFF
www.necvisualsystems.com
00H
CKS
01H
DATA00 CKS
DATA00 CKS
01H
DATA00 CKS
01H
DATA00 CKS
03H
DATA00 DATA01 DATA02 CKS
03H
03H
DATA00 DATA01 DATA02 CKS
03H
NEC Solutions (America), Inc.
(using four 42VM5 or 42VP5 Plasma Displays)
Visual Systems
v1.3
Page 10 of 14