Please read these instructions carefully before installation and operation.
Sensing Type | Photoelectric (Type A - contains no radioactive material) |
Power Supply | 220-240V AC 50Hz Replaceable DC 3V battery: Pairdeer/ Huiderui CR17450 |
Interconnectivity | Hard Wired |
Battery life | 10 year backup Lithium |
Wireless Option | Wireless Module SASWM |
Interconnection | Maximum 24 paired alarms Max wiring length between first and last alarm: 150 m |
Size | Φ135mm x 45mm |
Temp range | 0°C - 45°C |
Max Humidity | 93%RH |
"Alarm Signal Pattern" | ISO 8201 |
Alarm Volume | 85dB at 3m |
Hush Time | 10 mins |
Compliance | AS 3786: 2014 |
Certification | CSIRO Verification Service |
Where it is not possible to place the alarm on the ceiling, the smoke alarm may be installed on the wall at a minimum of 300mm and a maximum of 500mm off the ceiling at the junction of the wall.
There are special requirements for stairways, sloping ceilings and ceilings with exposed beams. Specific requirements are explained in the relevant Building Regulation.
(Exposed joists or other projections such as exposed beams, rafters, trusses, etc.)
To reduce the likelihood of nuisance alarms, it is preferable that smoke alarms are not located near cooking appliances, bathrooms or laundries
Notes: Terminal cover is supplied temperately in accessory bag, make sure the terminal cover is installed after wiring.
If more than one smoke alarm is installed all units shall be interconnected or paired.
Interconnection can be achieved either by wiring the I-Connect terminals of the alarms together or pairing using the optional wireless module (not included).
The smoke alarm can be paired with Voltex Battery Smoke Alarm type SAS115BW when fitted with a Wireless Module (not included), Voltex Part number SASWM. See SASWM instructions for pairing procedure.
The smoke alarm should not use both wireless and hardwired interconnections. The interconnection will not function if both are used at the same time.
NOTE:
DO NOT CONNECT INTERCONNECTION WIRE TO ACTIVE, NEUTRAL OR EARTH
NOTE: ONLY VOLTEX SMOKE ALAMRS CAN BE INTERCONNECTED TO EACH OTHER
In the event of an alarm condition, pressing the HUSH button on the alarm unit will silence the alarm for approximately 10 minutes.
NOTE: Where multiple alarms are interconnected, the HUSH function WILL NOT OPERATE EXCEPT ON THE UNIT THAT THE ALARM WAS TRIGGERED FROM. The triggered unit can be identified by the RED LED flashing.
When the unit indicates a low battery alarm or internal fault, pushing the HUSH button will silence the alarm for 10 hours and the red LED will flash every 40 seconds.
OPERATION MODE | RED LED STATUS | SOUND |
Power Up | Flash | No beep for no wireless interconnection. No beep for hard wired interconnection. Beep once when wireless module is installed & paired. Beep 3 times when wireless module is installed but NOT paired. |
Alarm functioning correctly (standby) | Low intensity flash every 40 seconds | - |
Low battery warning | Flash every 40 seconds | One chirp every 40 seconds. Press HUSH button enter 'Do Not Disturb' Mode for 10 hours. |
Fault warning | Flash every 40 second | One chirp every 40 seconds. Press HUSH button enter 'Do Not Disturb' Mode for 10 hours. |
Self-test fault warning | Flashes twice every 40 seconds | - |
HUSH mode | Flash once every 8 seconds for 10 min | - |
Do not Disturb | Flash once very 40 seconds for 10 hours | - |
Smoke detected on local alarm* | Flash every second | Continuous alarm signal pattern, Press HUSH button to enter Silent Mode for 10 min |
Smoke detected on interconnected or paired unit | - | Continuous alarm signal pattern, Press HUSH button to enter Silent Mode for 10 min |
Test function | Flash every second | Continuous alarm signal pattern until TEST button released |
Weekly self-test | Flash once | Chirps once every week |
End of Life (10 year) Warning | Flashes twice every 40 seconds | Chips every 40 seconds Cannot enter 'Do Not Disturb' Mode. |
*Continuous alarm pattern: Beep 0.5s- Pause 0.5s- Beep 0.5s- Pause 0.5s-Beep 0.5s- Pause 1.5s repeatedly per ISO 8201 Smoke is detected, and the building must be vacated immediately. Emergency services must be notified.
NOTE: If self-test fault warning is existing, but the product can sound alarm when press the test button. The product can continue to be used. Need to test weekly by press the test button instead of self-test weekly.
In an interconnected group, only the LED on the triggered alarm flashes once approximately every 20 seconds for 72 hours. This can be used to identify the triggered unit.
Problem | Solution |
Green LED not lit | Check mains power connection |
Hard wire paired smokes don't alarm during test | Check if Smoke Alarms are in same circuit, interconnect cable is corrected firmly and mains power is connected. |
Wireless interconnected smoke alarms don't alarm during test | Clean the wireless paired smoke alarm per instruction and repair. |
Alarms sound for no apparent reason | Check for fumes, steam, etc. from the kitchen or bathroom. Paint and other fumes can cause nuisance alarms. Check for any sign of contamination such as cobwebs or dust. Clean the alarm. |
Press the local Hush button to silent the Smoke Alarm triggered, identify the alarm that triggered by the flashing red LED (alarm will not silence if it does not have a flashing red LED) | |
If cannot hush the smoke alarm, push the button located on the side and open the Smoke Alarm, take off the battery. Contact Voltex. | |
Chirp every 40 seconds and cannot hush | Check if battery has been installed firmly, contact Voltex |
Dust and insect Contamination | Vacuum the outside of the Smoke Alarm to remove any dust build up. Smoke Alarm are prone to dust and insect ingress which can cause false alarm, it is prudent to clean the smoke alarm periodically. |
Voltex warrants this accessory against defective workmanship and faulty materials for seven (7) years from the original date of purchase.
Australia
www.voltexelectrical.com.au
P:1300 722275 E: sales@voltexelectrical.com.au
New Zealand
www.voltexelectrical.co.nz
P: 08005566 33 E: sales@voltexelectrical.co.nz
© Voltex Electrical 2020. All Rights Reserved.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Need help?
Do you have a question about the SAS135MH and is the answer not in the manual?
Questions and answers