Important Safety Information
¬
This Voltex Smoke Alarm is designed for use in
residential dwellings. It is intended to detect smoke
before it reaches the sleeping occupants of a
building. The ensuing alarm is designed to wake the
occupants and give them time to evacuate the building.
¬
This smoke alarm SHALL be installed in accordance
with national and local council building regulations
and the latest edition of the Australian and New
Zealand wiring Rules AS/NZS 3000. Building codes
and regulations may vary from each state jurisdiction.
¬
The smoke alarm incorporates a non-replaceable
battery which is manufactured to power the
smoke alarm for at least 10 years without being
recharged subject to normal
use and regular
maintenance from the date of manufacture.
Recommended Installation Locations
¬
At least one smoke alarm shall be fitted on each storey
(including basements) - in each bedroom and in corridors
or hallways which connect bedrooms and the rest of
the dwelling or as required by relevant local legislation.
¬
Where practicable smoke alarms should be placed on
the ceiling.
¬
It is important to install the smoke alarm in the centre
of the room, avoiding dead air spaces (an area in which
trapped hot air will prevent smoke from reaching the
alarm). Smoke alarms must not be placed within:
300mm of a corner of a ceiling and a wall
300mm of a light fitting
400mm of an air-conditioning vent
400mm of the blades of a ceiling fan
¬
Smoke alarms must be paired (interconnected) with
every other smoke alarm so they all activate together
Recommended locations
Where it is not possible to place the alarm on the ceiling,
the smoke alarm may be installed on the wall at a minimum
of 300mm and a maximum of 500mm off the ceiling at the
junction of the wall.
There are special requirements for stairways, sloping ceilings
and ceilings with exposed beams. Specific requirements are
explained in the relevant Building Regulation.
Nuisance Alarms
To reduce the likelihood of nuisance alarms, do not install a
smoke alarm near cooking appliances, in bathroom, laundry
room, or close to heating and cooling supply vents.
Do not install a smoke alarm in dusty or dirty areas.
Do not install a smoke alarm where bugs or insects are
present.
SAS115BW SMOKE ALARM
USER MANUAL
Congratulations on purchasing a Voltex Smoke Alarm.
Please read these instructions carefully before installation
and operation.
Photoelectric (Type A - contains
Sensing Type
no radioactive material)
Non-replaceable 10 Year Lithium
Power Supply
Battery
Interconnectivity
Wireless (433.42MHz)
Wireless range
Up to 100m in open space
Interconnection
Maximum 40 paired alarms
Size
114mm x 38mm
Temp range
0°C - 45°C
Max Humidity
5%-95%RH
Alarm Signal Pattern ISO 8201
Alarm Volume
85dB at 3m
Hush Time
10 mins
Compliance
AS 3786:2014
Certification
CSIRO Verification Service
NOTE: Recently the wireless paring signal has changed. You
will ONLY be able to pair alarms marked with this symbol
on the inner box and sticker on rear of product.
Please contact Voltex on 1300 722 275 in case of needing to
pair with an earlier version.
AS 3786:2014
II301020-AZ

Advertisement

loading
Need help?

Need help?

Do you have a question about the SAS115BW and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Voltex SAS115BW

  • Page 1 Smoke alarms must be paired (interconnected) with Do not install a smoke alarm where bugs or insects are Please contact Voltex on 1300 722 275 in case of needing to every other smoke alarm so they all activate together present.
  • Page 2 Installation Procedure Alarm Memory NOTE: If the MASTER smoke alarm fails to pair within 30 seconds or the button is pressed again 3 times in 2 seconds the unit will return to normal standby mode. To continue pairing, repeat step d) and e). Once In an interconnected group, only the LED on the triggered Smoke alarms should be paired before mounting.