Voltex SAS115BW User Manual

Advertisement

Quick Links

Important Safety Information

¬
This Voltex Smoke Alarm is designed for use in
residential dwellings. It is intended to detect smoke
before it reaches the sleeping occupants of a
building. The ensuing alarm is designed to wake the
occupants and give them time to evacuate the building.
¬
This smoke alarm SHALL be installed in accordance
with national and local council building regulations
and the latest edition of the Australian and New
Zealand wiring Rules AS/NZS 3000. Building codes
and regulations may vary from each state jurisdiction.
¬
The smoke alarm incorporates a non-replaceable battery
which is manufactured to power the smoke alarm for at
least 10 years without being recharged subject to normal
use and regular maintenance from the date of manufacture.
¬
The recommended date for replacement shall be marked
at the time of installation on the rating label. If this date
is exceeded or a battery-low condition is indicated, the
smoke alarm shall be replaced.

Recommended Installation Locations

¬
At least one smoke alarm shall be fitted on each storey
(including basements) - in each bedroom and in corridors
or hallways which connect bedrooms and the rest of
the dwelling or as required by relevant local legislation.
¬
Where practicable smoke alarms should be placed on the
ceiling.
¬
It is important to install the smoke alarm in the centre
of the room, avoiding dead air spaces (an area in which
trapped hot air will prevent smoke from reaching the
alarm). Smoke alarms must not be placed within:
• 300mm of a corner of a ceiling and a wall
• 300mm of a light fitting
• 400mm of an air-conditioning vent
• 400mm of the blades of a ceiling fan
¬
Smoke alarms must be paired (interconnected) with
every other smoke alarm so they all activate together
Recommended locations
Where it is not possible to place the alarm on the ceiling,
the smoke alarm may be installed on the wall at a minimum
of 300mm and a maximum of 500mm off the ceiling at the
junction of the wall.
There are special requirements for stairways, sloping ceilings
and ceilings with exposed beams. Specific requirements are
explained in the relevant Building Regulation.

Nuisance Alarms

To reduce the likelihood of nuisance alarms, it is preferable
that smoke alarms are not located near cooking appliances
and bathrooms.
SAS115BW SMOKE ALARM
USER MANUAL
Congratulations on purchasing a Voltex Smoke Alarm.
Please read these instructions carefully before Installation
and Operation.
Photoelectric (Type A - contains
Sensing Type
no radioactive material)
Non-replaceable 10 Year Lithium
Power Supply
Battery
Interconnectivity
Wireless (433.42MHz)
Wireless range
Up to 100m
Interconnection
Maximum 40 paired alarms
Size
114mm x 38mm
Temp range
0°C - 45°C
Max Humidity
93%RH
Alarm Signal Pattern ISO 8201
Alarm Volume
85dB at 3m
Hush Time
10 mins
Compliance
AS 3786
Certification
CSIRO Verification Service

Warranty Information

Voltex warrants this accessory against defective workmanship
and faulty materials for seven (7) years from the original date
of purchase. Please retain proof of purchase.
AS 3786:2014
II190514-BO

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SAS115BW and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Voltex SAS115BW

  • Page 1 Important Safety Information ¬ This Voltex Smoke Alarm is designed for use in residential dwellings. It is intended to detect smoke before it reaches the sleeping occupants of a building. The ensuing alarm is designed to wake the SAS115BW SMOKE ALARM occupants and give them time to evacuate the building.
  • Page 2 NOTE: Smoke alarms can be paired and unpaired Alarm functioning Low intensity flash 2. Take the smoke alarms into the rooms where they will be indefinitely. The SAS115BW is only compatible with correctly every 40 seconds installed and perform Wireless Test Procedure.

Table of Contents