INSTALLATION MANUAL
EN - Version 1.0
PROTECT 800i C™ / 1500i C™ is designed to protect the most common
premises. Private homes and garages, shops and stores, offices, and
small and medium-sized warehouses.
The two new Fog Cannons™ are built on the same platform, but one
is sized for several cubic meters of fog and can fire for longer than
the other. Many of the specifications are otherwise similar.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 800i C and is the answer not in the manual?

Questions and answers

Summary of Contents for Protect 800i C

  • Page 1 PROTECTGLOBAL.COM INSTALLATION MANUAL EN - Version 1.0 PROTECT 800i C™ / 1500i C™ is designed to protect the most common premises. Private homes and garages, shops and stores, offices, and small and medium-sized warehouses. The two new Fog Cannons™ are built on the same platform, but one is sized for several cubic meters of fog and can fire for longer than the other.
  • Page 2: Table Of Contents

    10. Approvals and certifications ......19 11. APPENDIX Manual for PROTECT IPCard™ ......23 SECURED IN SECONDS...
  • Page 3: Before You Begin

    PROTECT 800i C 1500i C INSTALLATION MANUAL ™ ™ 1. Before you begin Start by reading this manual - the included quick By now you should have completed our installation guide cannot stand alone. course. That may be a requirement.
  • Page 4: Safe Instructions And Best Practice

    PROTECT 800i C 1500i C INSTALLATION MANUAL ™ ™ 2. Safe instructions and best practice To ensure the best possible coverage the fog The fog machine must be placed to ensure needs free passage. immediate coverage of possible access points.
  • Page 5 PROTECT 800i C 1500i C INSTALLATION MANUAL ™ ™ Measurements for installation of the fog machine. Minimum safety distance is 35 cm for people and objects. Do not look directly into the nozzle at a short distance - risk of scalding!
  • Page 6: Mounting

    Place the Fog Cannon™ on the attached mounting Cabling of PROTECT 800i C™ / 1500i C™. plate. Important! Remember to screw the safety One cable to the alarm system, and the other screw back in before you continue working.
  • Page 7: Connection And Settings

    PROTECT 800i C 1500i C INSTALLATION MANUAL ™ ™ 4. Connection and settings Printed circuit board (PCB) Voltage PROTECT 800i C ™ PROTECT 1500i C ™ 230 V - 50 Hz 230 V - 50 Hz Effect PROTECT 800i C ™...
  • Page 8 PROTECT 800i C 1500i C INSTALLATION MANUAL ™ ™ Connection to alarm panel (typical installation) SECURED IN SECONDS...
  • Page 9 PROTECT 800i C 1500i C INSTALLATION MANUAL ™ ™ Dipswitch Function Heat disable ON = The heating element disconnects if disable is activated Fog time Fog time Fog time Arm* Primary* Secondary* Fire-alarm delay ** Reserved. Leave in OFF position Error indicator.
  • Page 10 The reduction in visibility at 1m during the tests carried out during the NF&A2P 2 shield certification (EN 50131-8: 2019 and RTC 50131-8) of the 800i C™ is 50 sec. for 150 m 1136 sec. for maintaining opacity up to 3m.
  • Page 11 PROTECT 800i C 1500i C INSTALLATION MANUAL ™ ™ PROTECT 1500i C ™ Dip settings Fog time Fog volume Dip 2 Dip 3 Dip 4 m³ demo 20 sec 40 sec 60 sec 1350 80 sec 1600 80 sec + 4 min.
  • Page 12: Test And Hand Over

    PROTECT 800i C 1500i C INSTALLATION MANUAL ™ ™ 5. Test and hand over Loosen the nozzle with a wrench (17) if changing Check the control signals before testing. angle and/or direction of the fog (up to 30°). Fasten again with the same tool.
  • Page 13 PROTECT 800i C 1500i C INSTALLATION MANUAL ™ ™ Check the fluid level after testing (hand over the Remember to put warning labels on the fog machine with a full fluid container). windows/doors. PROTECTGLOBAL.COM WARNING SECURITY FOG SYSTEM INSTALLED Before leaving the installation all users must be The users must be informed that further information instructed in how the fog machine works.
  • Page 14: Error Messages And Troubleshooting

    In case of error, read the error code on the Fog Cannon’s LED display and the error code description below. We refer to PROTECT IntelliSuite™ V.2.50.0.0, which is a free diagnostic tool used with the PROTECT Intelli- Connector™ cable or with remote access via integrated PROTECT IPCard™.
  • Page 15 Pull out the 4-pole plug next to the glass fuses. Use an Ohm meter and measure between the white and the brown wire. The resistance shall be approx.: 800i C™: 53 Ohm 1500i C™: 41 Ohm Note that the values can fluctuate 2-3 Ohm.
  • Page 16 PROTECT 800i C 1500i C INSTALLATION MANUAL ™ ™ E13: The built-in 12 V supply overloaded due to congestion. Too much extra equipment connected to the 12V supply or there is a short cut in connected equipment. Remove the overload or repair the short cut.
  • Page 17: Warnings

    The electrical connections of the Fog Cannon™ must If the above instructions are not observed, PROTECT only be handled by certified electrical fitter. The A/S shall not be liable for any consequences resul- system MUST be connected to earth to meet electri- ting from such non-observance.
  • Page 18: Consequences Of The Use Of Unauthorized Fluid In Protect Fog Cannons

    The PROTECT™ security fog fluid has an expiration vice/test the system once a year. Servicing/tests time of 2 years from the installation of the fluid must be carried out by an alarm technician.
  • Page 19: Approvals And Certifications

    PROTECT 800i C 1500i C INSTALLATION MANUAL ™ ™ 10. Approvals and certifications Models 800i C™ and 1500i C™ are NF&A2P 2 shields certified according to the NF324-H58 standard Certifying organization: AFNOR (www.marque-nf.com) and CNPP (www.cnpp.com). Applicable standards: EN 50131-8:2019 & RTC 50131-8. Certificate numbers: 9024000001A0 & 9024000002A0. Protection index: IP 20. Mechanical shock protection index: IK08.
  • Page 20 PROTECT 800i C 1500i C INSTALLATION MANUAL ™ ™ Organisme certificateur Organisme certificateur AFNOR Certification CNPP Cert. 11, rue Francis de Pressensé Route de La Chapelle Réanville – CS 22265 93571 LA PLAINE SAINT-DENIS Cedex 27950 LA CHAPELLE LONGUEVILLE  : (33) 1.41.62.80.00 ...
  • Page 21 PROTECT 800i C 1500i C INSTALLATION MANUAL ™ ™ Organisme certificateur Organisme certificateur AFNOR Certification CNPP Cert. 11, rue Francis de Pressensé Route de La Chapelle Réanville – CS 22265 93571 LA PLAINE SAINT-DENIS Cedex 27950 LA CHAPELLE LONGUEVILLE  : (33) 1.41.62.80.00 ...
  • Page 22 PROTECT 800i C 1500i C INSTALLATION MANUAL ™ ™ SECURED IN SECONDS...
  • Page 23: Appendix Manual For Protect Ipcard

    IPCard™. In general, PROTECT™ will not support basic networking problems since networking issues can be very complex and depends on local IT-planning, IT-politics and the way things are done in individual installa- tions.
  • Page 24: Networking Security And Safety

    Some prefabricated cables come with a strain relief that extends behind the connector. This type of connec- tor (as shown on the left) will not fit inside the cabinet of the PROTECT 800i C™/1500i C™ fog machines since it will conflict with the top cover of the Fog Cannon™. Please use RJ45 connectors as shown to the right.
  • Page 25: Technical Data

    PROTECT 800i C 1500i C INSTALLATION MANUAL ™ ™ 4. Technical data Inputs Type Optically isolated Bidirectional DC input Activation level (guaranteed ON) 7 – 30VDC (Max) Not activated (guaranteed OFF) 0 – 1VDC Current 2mA@12V, 4mA@24V Outputs Type Optically isolated Bidirectional output...
  • Page 26: Setting Up The Ipcard

    PROTECT 800i C 1500i C INSTALLATION MANUAL ™ ™ Please note that dipswitch settings, on the IPCard™, may be manipulated during normal operation. This will however reset program flow on the IPCard™ back to its initial stage for that particular setting.
  • Page 27: Network Settings

    PROTECT 800i C 1500i C INSTALLATION MANUAL ™ ™ 5.1 Network settings Under the menu item [IPCard™ Network Setup] you will be able to setup all basic networking parameters and get information on MAC-address, current IP-address etc. Remember to use the button “Set and restart” to store any changes you make.
  • Page 28: Using Intellisuite™ For Monitoring And Controlling The Fog Cannon

    Port forwarding performed in routers etc. may affect the port number you will have to type in You may also password protect you endpoint list from a remote network. by changing the master password. This will encrypt any information specified in the endpoint list.
  • Page 29: Options With Ipcard

    7.1. Panic function mode Software requirements Fog Cannon™: Software version 4.00 or higher. Software requirements IPCard™: Software version 1.09 or higher. Device requirements: This program will run on any type of PROTECT Fog Cannon ® Dipswitch settings SECURED IN SECONDS...
  • Page 30 PROTECT 800i C 1500i C INSTALLATION MANUAL ™ ™ Inputs functionality IN-1 Panic button functionality (normally open) IN-2 Disable signal (this Disable input allows Panic to work - will not turn off heat), (normally open) Outputs functionality OUT-1 Panic release active...
  • Page 31 Scandinavia. PROTECT ™ is represented worldwide in 50 countries. Learn more on protectglobal.com SECURED IN SECONDS PROTECT A/S · Hasselager Centervej 5 · DK-8260 Viby J · Tel.: (+45) 86 72 18 81 · Mail: info@protectglobal.com...