QUICK GUIDE
QUICK GUIDE
5-year warranty
PROTECT 800i C™ and 1500i C™ automatically
come with a 5-year-warranty! Learn more on
Protectglobal.com/service-support/warranty
PROTECTGLOBAL.COM
Free technical E-learning
We offer free technical e-learning courses about
installation of Fog Cannons™.
Enroll on protectglobal.com/e-learning

Advertisement

loading
Need help?

Need help?

Do you have a question about the 800i C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Protect 800i C

  • Page 1 PROTECTGLOBAL.COM QUICK GUIDE QUICK GUIDE 5-year warranty Free technical E-learning PROTECT 800i C™ and 1500i C™ automatically We offer free technical e-learning courses about come with a 5-year-warranty! Learn more on installation of Fog Cannons™. Protectglobal.com/service-support/warranty Enroll on protectglobal.com/e-learning...
  • Page 2 PROTECTGLOBAL.COM This quick guide does not replace the installation manual and the recommended technical training course for installers. DIP switch 10 should be set to ON to let the acoustic alarm activate in case of a fault. REMEMBER to set the fog time on DIP switch 2, 3 and 4. Tables for fog time and DIP switch settings, together with QR codes for the installation manual, are displayed in this quick guide.
  • Page 3: Printed Circuit Board (Pcb)

    PROTECTGLOBAL.COM Printed circuit board (PCB) Voltage Max. Effect PROTECT 800i C ™ PROTECT 1500i C ™ PROTECT 800i C ™ PROTECT 1500i C ™ 230 W - 50Hz 230 W - 50Hz 1050 W 1350 W Standby consumption after heating up (on average)
  • Page 5 PROTECT MultiCard™ Ajax MultiTransmitter Outgoing feedback option. IntelliCloud™, free cloud based feedback - use PROTECT IPCard™ expansion card to provide feedback via smartphone or PC. Internet connection required via RJ45. Outgoing feedback option. Use Ajax wireless output relays, eg: door contacts to provide.
  • Page 6 Fog Cannon to become Ajax ready, this software, version 3.11, can be found on the PROTECT Download Center. IntelliConnector required. Ajax relays can be after installed in all PROTECT Fog Cannons® using a complete kit from PROTECT. PROTECT IntelliConnector™...
  • Page 7: Mounting And Positioning

    For horizontal mounting, place the Fog Cannon™ as shown Check the control signals before testing Remember to heat the system before testing in the picture Min. 10 cm PROTECT 800i C PROTECT 1500i C Min. 10 -15 15 -25 Check the fluid level after testing (hand over the fog...
  • Page 8: Dip Switch Settings

    Reserved. Leave in OFF position Error indicator On = Beeper connected ON = normal open OFF = normal closed ** ON = delay is active PROTECT 800i C DIP Settings Fog Time Fog Volume DIP 2 DIP 3 DIP 4 m³...