7 Operation
Always turn OFF the power and ensure that no power is being supplied to the 
pump when attaching or disconnecting wiring. Failure to observe this could result 
in electric shocks.
Do not pour water into the motor. Failure to observe this could result in electric 
shocks, short circuit, fires, and malfunction.
Always turn the power switch OFF under a power failure. when a power supply 
returns, suddenly operation could in injuries.
Do not bring hands and feet close to a suction port during operation. Failure to 
observe this could result in injuries by being inhaled.
Do not use or perform work while the product is suspended. There is risk of 
dropping and injury.
Do not start operation with the shaft joint guard removed. Objects could get caught 
in or contact the rotating section and fly around and cause injury.
Do not use this product out of the rated voltage. Failure to observe this could result 
in fires or electric shocks.
Do not touch the rotating area during operation, and do not insert fingers or rods, 
etc. into the motor openings. Failure to observe this could result in electric shocks 
and injuries.
Do not touch pump or motor during operation . The motor could reach high 
temperature and lead to burns.
Turn OFF the power when not using the pump for long periods of time. Failure to 
observe this could result in earth leakages, electric shocks, or fire due to 
deterioration of the insulation.
Do not use the product over the frequency 60Hz (50Hz only model is 50Hz)  when 
driven with an inverter. Failure to observe this could result in the pump burning 
out or fires.
When operating the motor with a 400V class inverter, install a suppressing filter or 
reactor on the inverter side , or reinforce the motor side with insulation. Failure to 
observe this could lead to damage or fires due to insulation breakage.
Do not use a fluid with a higher viscosity than the maximum limit of viscosity.
 Failure to observe this could result in the pump burning out or fires.
Do not place flammable objects near the pump. Failure to observe this could result 
in fires if a power plug generates heat and ignites.
When resuming operation after a long-term storage or suspension, refer to the 
 "Installation" and "Operation" sections and perform trial operation. The pump could 
be locked and the motor could burn if parts are stuck, etc.
Always operate the pump within the specified range. Operation exceeding the 
specified range could result in pump damage or accidents.
7.1 Trial operation
  1.Verify that the earth leakage breaker capacity, the power supply voltage, and the  
    wiring are correct.  
  2.Check that the fluid is above the specified level.(Refer to 4 . 1 - 6)
  3.Turn the power ON, and confirm the rotation direction of the pump accords with the 
    arrow on the fan cover . If 3-phase rotation is reversed, turn the source power supply 
    OFF, then replace the connections of 2 of the 3 wires. 
  4.Confirm that coolant or cutting oil are discharged . Verify that the voltage, current,  
    vibration, and noise conditions, etc., are no abnormality.
Warning
Caution