Set The Condensation Prevention Heater To Min; Fine Adjustment Of The Temperature (Refrigerator Compartment / Freezer Compartment) - Hitachi R-SF48FJ How To Use Manual

Table of Contents

Advertisement

VARIOUS FUNCTIONS

Set the condensation prevention heater to MIN.

Setting the condensation prevention heater to MIN saves energy.
When dew is formed in the swing partition or the partitioning iron plates, set it to the standard.
The temperature settings for the swing partition and the partitioning iron plates can be adjusted by four levels (1 to 4),
and level 4 is the most energy saving.
MIN setting of the
heater
Preset sound
Setting the swing partition
1
Open the door of the Lower Freezer Compartment.
2
Press down
button 3 seconds or
more until the preset
sound is heard.
Settings of condensation prevention heater will be changed.
Repeat the change of settings to set the operation sound you
like (See the table shown above).
3
Close the door of the Lower Freezer Compartment.
● The setting will be returned to the standard when the power plug is disconnected and connected or power failure recovery takes place.
Notice
Fine adjustment of the temperature
Temperature settings for Refrigerator and Freezer Compartments can be more finely adjusted by 11 levels.
1
Open the door of the Lower
Freezer Compartment.
2
Press down
seconds or more until 1 beep is
heard.
3
Close the door of the Lower
Freezer Compartment.
56
MIN setting
Standard
level 1
Long beep
(Factory setting)
button for 5
(CONTINUED)
(Swing partition/Partitioning iron plates)
MIN setting
MIN setting
level 2
level 3
Long beep (2 beeps) Long beep (3 beeps) Long beep (4 beeps)
Setting the partition plate
1
Open the door of the Lower Freezer Compartment.
2
Press down
button 3 seconds or
more until the preset
sound is heard.
Settings of condensation prevention heater will be changed.
Repeat the change of settings to set the operation sound you
like (See the table shown above).
3
Close the door of the Lower Freezer Compartment.
(Refrigerator Compartment / Freezer Compartment)
4
Push
or
adjustment.
Each time you touch the button, the corresponding indicator lamp
changes in the order shown below.
Usually it is recommended to use it at the setting of " 中 (MID) " .
(
Lighting
Blinking
Indication
lamp
Setting
MI N and under MIN.
Follow the operations shown in Step 1, 2 and 3.
2 beeps sound and you can set the temperature by normal step (3 levels).
Swing partition
Partitioning iron plates
MIN setting
Standard
level 4
2 beeps
button to make an
Turned off)
MID.
MAX. MAX and more