Inductance decade box
Hide thumbs Also See for 1053:

Advertisement

Quick Links

User Manual
1053
Inductance Decade Box
Version 1.2
11-22
Time Electronics Ltd
Unit 5, TON Business Park, 2-8 Morley Road,
Tonbridge, Kent, TN9 1RA, United Kingdom.
T: +44 (0) 1732 355993 | F: +44 (0) 1732 350198
mail@timeelectronics.co.uk | www.timeelectronics.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the 1053 and is the answer not in the manual?

Questions and answers

Summary of Contents for Time Electronics 1053

  • Page 1 User Manual 1053 Inductance Decade Box Version 1.2 11-22 Time Electronics Ltd Unit 5, TON Business Park, 2-8 Morley Road, Tonbridge, Kent, TN9 1RA, United Kingdom. T: +44 (0) 1732 355993 | F: +44 (0) 1732 350198 mail@timeelectronics.co.uk | www.timeelectronics.com...
  • Page 2 All rights reserved. Nothing from this manual may be multiplied, or made public in any form or manner, either electronically or hard copy, without prior written consent from Time Electronics Ltd. This also applies to any schematics, drawings and diagrams contained herein.
  • Page 3: Table Of Contents

    Time Electronics 1053 Inductance Decade Box User Manual Contents Introduction ............................ 2 Specifications ..........................3 Operation ............................4 Safety Precautions ..........................4 Front Panel Controls and Connections ....................4 Operating Instructions ........................... 5 Inductance Setting Table ........................7 Warranty and Servicing ......................... 8...
  • Page 4: Introduction

    A precision decade inductance box suitable for filter design, experimental, general purpose substitution, and DC to DC converter design. The 1053 is housed in a fully screened robust metal case and is both compact and durable, making it ideal for laboratory or field use.
  • Page 5: Specifications

    Time Electronics 1053 Inductance Decade Box User Manual Specifications Range / Resolution ....0 to 10 H / 1mH steps. Decade 1 mH 10 mH 100 mH Accuracy at 1 kHz ± 3 % ± 3 % ± 3 % ±...
  • Page 6: Operation

    Time Electronics 1053 Inductance Decade Box User Manual Operation Safety Precautions Observe proper safety operational guidelines when working with high voltages. To minimize shock hazard connect the case terminal to an electrical ground. Always take precautions to avoid and prevent contact with live components.
  • Page 7: Operating Instructions

    Time Electronics 1053 Inductance Decade Box User Manual Operating Instructions 3.3.1 Connections Connection to the decade box is via 4 mm safety terminal posts, using 4 mm shrouded or standard plugs. Alternatively, crocodile clips or stripped wire connections can be used.
  • Page 8 • Set the 1 mH dial to 2. For a quick reference to the setting values of the 1053, please see the Inductance Setting Table on the following page. Note: All inductance boxes have a residual inductance, meaning that when the dials are set to zero a small inductance remains.
  • Page 9: Inductance Setting Table

    Time Electronics 1053 Inductance Decade Box User Manual Inductance Setting Table The below table shows the settings of each inductance decade using the dials. 1 H Decade 100 mH Decade 10 mH Decade 1 mH Decade Dial Dial Dial Dial...
  • Page 10: Warranty And Servicing

    Time Electronics’ total liability is limited to repair or replacement of the product. Note that if Time Electronics determine that the fault on a returned product has been caused by the user, we will contact the customer before proceeding with any repair.
  • Page 11 User Manual Returning Instruments Prior to returning your product please contact Time Electronics. We will issue a return merchandise authorization (RMA) number that is to accompany the goods returning. Further instructions will also be issued prior to shipment. When returning instruments, please ensure that they have been adequately packed, preferably in the original packing supplied.