red lion 5RLAG-2LKIT Owner's Manual

red lion 5RLAG-2LKIT Owner's Manual

Engine-driven aluminum water pump

Advertisement

Quick Links

EN
ENGLISH
ENGINE-DRIVEN
ALUMINUM WATER PUMP
5RLAG-2L 5RLAG-2LKIT
Owner's Manual

Table Of Contents

Safety Instructions ............................................................................... 2
Introduction ..........................................................................................4
Application ...........................................................................................4
Specifications .......................................................................................4
Pump Placement ................................................................................. 5
Operation .............................................................................................. 5
Maintenance ......................................................................................... 7
Cleaning ................................................................................................ 7
Draining the Pump .............................................................................. 8
Transporting the Pump ....................................................................... 8
Storage ................................................................................................. 8
Troubleshooting ...................................................................................9
Replacement Parts .............................................................................10
Limited Warranty .................................................................................11

Advertisement

Table of Contents
loading

Summary of Contents for red lion 5RLAG-2LKIT

  • Page 1: Table Of Contents

    ENGLISH ENGINE-DRIVEN ALUMINUM WATER PUMP 5RLAG-2L 5RLAG-2LKIT Owner's Manual Table Of Contents Safety Instructions ................2 Introduction ..................4 Application ...................4 Specifications ..................4 Pump Placement ................. 5 Operation ....................5 Maintenance ..................7 Cleaning ....................7 Draining the Pump ................8 Transporting the Pump ...............
  • Page 2: Safety Instructions

    Failure to comply with national and local electrical codes and • Keep work area clean, well-lit, and uncluttered. within Red Lion recommendations may result in electrical shock or fire • Keep safety labels clean and in good condition. hazard, unsatisfactory performance, or equipment failure.
  • Page 3 Product Specific Precautions Rental companies and private owners who rent or lend this pump to others: All persons to whom you rent or lend this pump must have access Risk of bodily injury or equipment damage. to and read the product’s owner's manuals. Keep the manuals with the •...
  • Page 4: Introduction

    15.5" (39.4 cm) Width 14.5" (36.8 cm) Length 18.0" (56.7 cm) *5RLAG-2LKIT contains 1 of 5RLAG-2L plus the following accessories: 50' lay flat discharge hose with attached couplings, 12' reinforced suction hose, steel suction strainer and two 2" aluminum adapters.
  • Page 5: Pump Placement

    PUMP PLACEMENT Risk of injury or property damage from fire. • The pump must be at least 5 feet from structures having combustible walls and/or other combustible materials such as leaves, grass, and brush. • Reflective exhaust heat may damage the fuel tank, causing fire. Keep at least 3 feet of clearance on all sides of the pump for adequate cooling, maintenance, and servicing.
  • Page 6 Priming the Pump Risk of damage to equipment. • Do not operate the pump without priming it. Water is required to lubricate the pump seal. Operating the pump dry will permanently damage the pump seal. Be sure pump housing is completely filled with water before starting the engine. Remove the priming plug.
  • Page 7: Maintenance

    MAINTENANCE Risk of severe injury or property damage from fire or projectiles. • Never start or operate a pump known or suspected to be damaged, defective or malfunctioning. • Do not make adjustments or repairs to the pump or engine while engine is operating. •...
  • Page 8: Draining The Pump

    DRAINING THE PUMP Risk of injury or damage to equipment. • Do not remove priming plug, drain plug, pump housing or inlet or discharge hose fittings when pump is hot. Hot water and/or vapor inside could be pressurized. If the pump is subject to freezing temperatures, pump housing must be thoroughly drained of any water to prevent damage from freezing. Allow the unit to cool completely.
  • Page 9: Troubleshooting

    TROUBLESHOOTING Problems Causes Solutions Make sure suction hose is double clamped at joints, clamps are tight, fittings have Air leak in suction hose thread compound and are tight, with no nicks or cuts in hose The suction and/or discharge hose(s) may be blocked, Check to see that the hoses and valves are in good working order Pump will not pump or the valve(s) are closed, faulty and/or blocked...
  • Page 10: Replacement Parts

    REPLACEMENT PARTS REPLACEMENT PARTS ITEM # DESCRIPTION CONTENTS 5RLAG-2L 617301 10, 11, 32, 33, 35, 36, 39 Minor Repair Kit 5RLAG-2L 617311 10, 11, 13, 14, 32, 33, 34, 35, 36, 37 Major Repair Kit 5RLAG-2L 617321 9, 10, 11, 12, 15, 16, 17, 25 Casing Kit 5RLAG-2L 617330...
  • Page 11: Redlionproducts.com Limited Warranty

    THIS WARRANTY SETS FORTH THE BRAND’S SOLE OBLIGATION AND PURCHASER’S EXCLUSIVE REMEDY FOR DEFECTIVE PRODUCT. Engine and Emissions Control System (ECS): The Red Lion brand (hereafter “the Brand”) is not liable for the ECS or related components. Please refer to the engine manufacturer’s owner’s manual for details regarding the engine and emissions control system (ECS) warranties.
  • Page 12 THE BRAND SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES SUCH AS, BUT NOT LIMITED TO: DAMAGE TO OR LOSS OF OTHER PROPERTY OR EQUIPMENT, LOSS OF USE OF EQUIPMENT, FACILITIES OR SERVICE, LOSS OF PROFIT OR SALES, COST OF PURCHASES OR REPLACEMENT GOODS, CLAIMS OF CUSTOMERS OF THE PURCHASER, FAILURE TO WARN AND/OR INSTRUCT, LOSS OF OTHER PRODUCTS, OR COSTS OF ENVIRONMENTAL REMEDIATION, OR DIMINUTION IN PROPERTY VALUE.

This manual is also suitable for:

5rlag-2l

Table of Contents