Installation Guide – CAN/USA ® ® This guide contains the information required to install an Ecoflo Coco Polyethylene and Ecoflo Coco Polyethylene Pack option. The installation must be performed by a duly trained installer. A list of installers can be provided by contacting our customer service at 1 800 632-6356.
Page 2
* Refer to the drawings on Figure 1. ** The weights indicated are approximate (non-contractual) and provided for handling and lifting purposes only. ® NOTE: Refer to the dosage volume chart for the Ecoflo Coco Filter model.
Page 3
* Refer to the drawings on Figure 1. ** The weights indicated are approximate (non-contractual) and provided for handling and lifting purposes only. ® NOTE: Refer to the dosage volume chart for the Ecoflo Coco Filter model. Technical datasheets of models 5.7 and 7.3...
Page 4
* Refer to the drawings on Figure 2. ** The weights indicated are approximate (non-contractual) and provided for handling and lifting purposes only. NOTE: Refer to the dosage volume chart for the Ecoflo ® Coco Filter model.
Primary treatment can be done using a septic tank that meets local regulation. Some Ecoflo Coco Filters housed into polyethylene tank are available into a monobloc configuration (PACK unit) that combines both, the septic/primary tank and the Ecoflo Coco Filter. Consult technical datasheets and respective installation guides for more information on this Ecoflo Coco Filter configuration.
Page 6
Coco Filters and each model has different characteristics. Unit can be ® housed either in concrete, polyethylene or fiberglass reservoirs. The following table presents the different Ecoflo Coco Filter models available according to the surface area of the filtering medium and treatment capacity. All of these models are certified compliant with Standard NSF/ANSI 40.
Page 7
EC5 Model Series: ® Therefore, the ECP-370-P model refers to an Ecoflo Coco Filter that can treat 370 US gallons per day, housed into a watertight bottom polyethylene shell with an integrated pump for effluent discharge. 2.3 Influent pumping station (if required) When wastewater cannot be conveyed by gravity between the primary treatment ®...
The final dispersal system must be designed in accordance with Premier Tech Aqua guidelines and/or State or Local regulations. Location of components and specific instructions ® Components of a residential septic installation: separate septic/primary tank and Ecoflo model Septic/primary Septic/primary tank with ®...
Page 9
Finished landscaping vs base of Ecoflo lid (E) 2” (50 mm) 2.8, 3.4, 4.1 Unit max 2’ (60 cm) from the bottom of Seasonal High Groundwater Table (SHGT) vs. base of Ecoflo unit (Fp) the unit (See Figure 3) 5.7 and 7.3 do not install in saturated soil...
Page 10
Coco Filter. • The lid of the Ecoflo Coco Filter must be at least 2" (50 mm) above the surface of final landscaping grade. • Ensure an upslope interceptor drain or water diversion berm is installed to direct surface and/or ground water away from the Ecoflo module and soil absorption system;...
Coco Filter offers a variety of disposal/dispersal methods of treated effluent depending on local regulations). ® Here are a few methods suggested by Premier Tech Aqua (but not limited to). The effluent of the Ecoflo Coco Filter may be discharged into (as applicable): •...
Page 12
200 UFC/100 ml. For more information on PTA's DiUV, please consult ® The DiUV can either be integrated in the pump vault located inside the Ecoflo Coco Filter unit or installed separately in another containment vessel. The following table lists the technical specifications of the Premier Tech Aqua DiUV.
® Description of the polyethylene Ecoflo Coco Filter components Exploded view of models 2.8, 3.4 and 4.1 Exploded view of models 2.8, 3.4 and 4.1 – PACK option Component Material Description...
Page 14
Exploded views of models 5.7 and 7.3 DV models Component Material Descprition...
Coco Filter ® Excavate a sufficiently large area to free up approximately 30 cm (1') around the Ecoflo Coco Filter stand alone or PACK unit. Depending on soil conditions, it may be necessary to add a 150 mm (6") layer of 20 mm Ø (0–¾") clean stone that is free of organic matter or a layer of 20 mm Ø...
Page 16
® Connect the pipe of the Ecoflo Coco Filter while making sure to maintain a constant downslope over the entire length of the pipe toward the dispersal area or final discharge. Note that the soil under the pipes must be adequately compacted.
Page 17
® Connect the pipe of the Ecoflo Coco Filter while making sure to maintain a constant downslope over the entire length of the pipe toward the dispersal area. Note that the soil under the pipes must be adequately compacted. ®...
Page 18
6.2 Anchoring ® 6.2.1 Anchoring kit (models 2.8, 3.4 and 4.1) for Ecoflo stand alone When a single riser is installed on models 2.8, 3.4 and 4.1, the biofilter (stand alone) must be anchored with the geotextile provided to this effect before the final backfilling such as to maximize the stability of the unit.
Page 19
6.4.1 Models 5.7 and 7.3 • Unscrew and remove the packaging material from both accesses. • Remove the main and secondary accesses. The main access assembly includes the cover and the insulating panel. To remove the cover, unscrew the four lag screws in the corners. •...
Page 20
Using the 3/8” screws provided and a 9/16” socket driver (not provided), loosely fasten the riser through the hole above the pumping vault (1). Center the riser on the Ecoflo by running your hand alongside the riser’s outer rim and repositioning it if necessary.
Page 21
® Ecoflo Coco Filter while making sure to maintain a constant ® downslope along the entire length of the pipe to the inlet of the Ecoflo Coco Filter Note that the soil under the pipe must be adequately ® compacted. The Ecoflo Coco Filter is equipped with a standard flexible inlet adaptor.
Page 22
® 6.5 (Optional) On site pump tree assembly with screen filter for the Ecoflo Coco Polyethylene models 2.8, 3.4, 4.1, 5.7 and 7.3 series. For pressurized installation, it is the responsibility of the installer to supply the screen filter. Depending of the model you bought, the screen filter may be supply by Premier Tech Aqua (confirm with your regional supervisor if this part is included or not in your package).
Page 23
1½" diameter. Keep the extension section, as shown below. Extension section ® 4. On the existing Ecoflo Coco Filter pump, cut the ty-raps and untie the rope attached to the pump. Unscrew the pump’s support and adapter as shown on the image below.
Page 24
• ® When the pumping station is used, it is important to verify that the volume of water reaching the Ecoflo Coco Filter is of the order of 8–10 US gal. (30–40 L) per hydraulic event (approximately 10 tipping bucket cycles for models 5.7 and 7.3 or 20 tipping bucket cycles for models 2.8, 3.4 and 4.1).
Page 25
Connect the pipe between the primary tank and the Ecoflo unit to the water inlet of the Ecoflo Coco Filter while ® making sure to maintain a constant downslope along the entire length of the pipe to the inlet of the Ecoflo Coco ®...
Page 26
Feed pipe effluent pipe For the PACK model fill carefully by hand under the pipe ® which connects the septic tank and the Ecoflo unit to Max. level Gravity assure that there is no air gaps between the pipe and the...
Page 27
They are to serve exclusively connectors for the pump and alarm box. Effluent pipe ® 5.7 and 7.3 Ecoflo Coco Filter models Electrical diagram ® Premier Tech Aqua 27/32 Polyethylene Ecoflo Coco Filter– Installation Guide CAN/USA 339975 Rev. 5.0...
Page 28
235 US Gal Cut 4” (600 L) (680 L) (750 L) (660 L) (890 L) ® Float tree adjustment for Ecoflo Coco Filter (example model PACK) ptzone.premiertechaqua.com For more information consult “dosing volume and float adjustment” section. ® Premier Tech Aqua...
Page 29
Next, install the insulating panel and seal it in place using the two Premier Tech fasteners. ® Once in place, these fasteners hold the collar of the Ecoflo Coco Filter to the handle of the insulating panel. Finally, use the lag screws to close the main cover. Note that the owner has nothing in particular to do to begin using the system.
Page 30
Coco Filter • ® It is always recommended to use the lift loops built into the upper casing of the Ecoflo Coco Filter. • The lift loops must always be used in combination with lift straps or shackles of appropriate size and capacity.
Page 31
® Use the two (2) lift loops (or lift straps provided with the PACK unit) built into the upper casing of the Ecoflo Coco Filter to unload the unit. Otherwise, make sure to use a forklift with forks that are long enough to pass all ®...
Page 32
By respecting these guidelines, you contribute to the proper operation of your wastewater treatment system and ® increase the probability of extending the useful life of the filtering medium of your Ecoflo Coco Filter. Failure to abide by these guidelines may void the warranty, at Premier Tech Aqua’s discretion.
Need help?
Do you have a question about the Coco Filter EC7 Series and is the answer not in the manual?
Questions and answers