BANDELIN SONOREX TECHNIK MO16.2 Operating Instructions Manual

Oscillation

Advertisement

Quick Links

!
Operating Instructions
3 4
Oscillation
MO 16.2 / MO 40
Example 3 4 MO 16.2
The unit has to be strictly used according to the instruction manual.
Keep the unit away from children and from persons not instructed for correct use by means of these instructions.
In case of improper use, the manufacturer does not take any responsibility for safety and proper functioning. Unauthorized
changes/modifi cations will result in expiration of the !-conformity.
2816m GB/2014-05
1
65 years of experience in ultrasound

Advertisement

Table of Contents
loading

Summary of Contents for BANDELIN SONOREX TECHNIK MO16.2

  • Page 1 Operating Instructions Oscillation MO 16.2 / MO 40 Example 3 4 MO 16.2 The unit has to be strictly used according to the instruction manual. Keep the unit away from children and from persons not instructed for correct use by means of these instructions. In case of improper use, the manufacturer does not take any responsibility for safety and proper functioning.
  • Page 2: Table Of Contents

    Technical data ......................7 Copyright & limit of liability This document may not be reproduced, either in full or in extracts, without prior approval of BANDELIN electronic GmbH & Co. KG, hereinafter referred to as BANDELIN. The German original is the binding version of this document. Any difference in the translation is not binding and has no legal ef- fect.
  • Page 3: Safety Instructions - To Be Strictly Observed

    Safety instructions – to be strictly observed General • The ocillation may be used intended and according to this operating instructions only together with SONOREX TECHNIK RM - unit. From there additionally all safety instructions of the operating instructions of the used unit are valid. •...
  • Page 4: Purpose

    Purpose General description of the unit The electrically driven oscillation MO enables automatic movement of the baskets in tanks of the production line SONOREX TECHNIK RM. The oscillating movement of the parts to be cleaned reinforces the cleaning effi ciency of the ultrasonic irradiation and helps to remove dirt particles more effi ciently. The movement is generated by an electromechanically driven lifting rod with a bracket on which the basket is hung with its handles.
  • Page 5: Installation, Assembly And Connection

    Installation, assembly and connection lifting rod  Assembly of the bracket: bracket - Place the bracket onto the lifting rod and fi x it with the washer and the screw by hand. - Align the bracket to the front (see picture). guide tube - Hold the lifting rod with spanner 16 and fi...
  • Page 6: Cleaning And Care

    Tel.: +49-30-768 80 - 19 Fax: +49-30-773 46 99 Fax: +49-30-773 46 99 The general terms of delivery of BANDELIN electronic GmbH & Co. KG shall apply. Attention! Repairs may only be done by authorized technicians or by the manufacturer.
  • Page 7: Technical Data

    Technical data SONOREX TECHNIK units are RFI-proofed and marked !. In conformity with DIN EN 60204-1, the limits as per EN 61000-6-1 and EN 61000-6-3. MO 16.2 MO 40 Mains supply: 230 V~ (± 10 %) 50/60 Hz, cable length 2 m stainless steel 1.4301 (AISI 304), Housing: drip-proof (IP 32)
  • Page 8 If service is required, please contact your supplier. BANDELIN electronic GmbH & Co. KG 65 years of experience in ultrasound Heinrichstraße 3 – 4 • 12207 Berlin www.bandelin.com Certifi cation GERMANY info@bandelin.com EN ISO 9001:2008 • EN ISO 13485:2012 Tel.: +49 30 768 80-0 • Fax: +49 30 773 46 99...