High-power ultrasonic baths and rinsing baths (34 pages)
Summary of Contents for BANDELIN BactoSonic
Page 1
User instructions BactoSonic Ultrasonic special bath Ultrasonic bath BS 14 6366-006 GB/2020-09...
Page 2
Copyright & limitation of liability This document may not be reproduced, either in full or in extracts, without prior approval of BANDELIN electronic GmbH & Co. KG, hereinafter referred to as BANDELIN. The German original is the binding version of this document. Any diff erence in the translation is not binding and has no legal eff ect.
Page 3
Operating sequence Identifi es instructions that are to be followed in the described instructions sequence. 6366-006 GB/2020-09 3 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
Cleaning and maintenance of the ultrasonic bath ............20 Cleaning and care ......................20 Disinfection ........................20 Positioning / Storage ....................20 Maintenance and repair ....................21 4 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
Page 5
Taking the unit out of service ..................25 Key words ........................26 Informative appendices Scope of supply BactoSonic 14.2 Optional accessories Foil test 6366-006 GB/2020-09 5 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
This produces an especially homogeneous and uniform ultrasound fi eld in the bath volume for constantly reproducible results. 6 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
Purpose Gentle separation of biofi lms (main application) The BactoSonic ultrasonic bath may be used to detach biofi lms gently from the surface of infected implants, as part of the scientifi cally-funded "Processing of implants using sonication methods". The microorganisms that are obtained in this manner are available for analysis following cultivation and make a prompt diff...
In order to improve the eff ect, the ultrasound is modulated whereby, depending upon the ultrasonic bath, a 4-fold -ultrasonic nominal output value is yielded as ultrasonic peak power. 8 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
During operation, portable or mobile HF communication systems in the vicinity of the ultrasonic bath should be turned off - their operation may be disrupted. 6366-006 GB/2020-09 9 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
Advice for the medical fi eld • The ultrasonic bath is exclusively intended for use by medical skilled personnel. 10 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
• The ultrasonic bath must be positioned in such a way that disconnection from the power supply is easily possible. 6366-006 GB/2020-09 11 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
• For foil tests, for degassing and cleaning, etc., the power selection switch must be set to 100% P. 12 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
• An “engaging” of the time switch is barely felt if mains voltage is not present, e.g. if the mains plug is disconnected or the fuse is blown. The time switch only works if mains voltage is present. 6366-006 GB/2020-09 13 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
For this purpose, the objects to be treated are placed in a basket and hung inside the oscillating tank which is fi lled with bath liquid. Bath fl uid 14 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
• The fl uid in the oscillating tank must not exceed a maximum operating temperature of 100°C. MILLNER, R.: Wissenspeicher Ultraschalltechnik, Fachbuchverlag publishing house, Leipzig 1987 6366-006 GB/2020-09 15 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
Set the power selection switch to 100% P. Switch ultrasound on for 10 min, see chapter 3.1.2 16 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
Page 17
Verify that the objects to be treated are fully covered by fl uid. With every object inserted, the fi ll level is to be monitored. 6366-006 GB/2020-09 17 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
Page 18
After emptying the oscillating tank, rinse it thoroughly. Then dry with a soft cloth. For further care instructions, see chapter 5. 18 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
In every case, the statutory provisions and regulations of municipal wastewater plants are to be adhered to. Information is provided by municipal wastewater plants as well as by environmental agencies. 6366-006 GB/2020-09 19 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
During long periods of non-use, the ultrasonic bath is to be stored in a cool, dry location. The lid should be placed on top in order to protect the oscillating tank from outside contamination. 20 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
Next, the value displayed is to be compared with the corresponding value in the technical data (chapter 1.4) (tolerances ± 20 %). 6366-006 GB/2020-09 21 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
The form can be downloaded from the Internet as a PDF fi le: www.bandelin.com / Service / Download ... 22 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
- After inspection, exchange only the defective fuses. - Replacement fuses are located on the base plate. Assembly in reverse order. 6366-006 GB/2020-09 23 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
Exceptions to this rule are special baskets and basket holders (e.g., K 6 and SH 7) that have been designed by BANDELIN in such a manner that they do not lie in the cavitation fi eld and do not damage the tank bottom.
• Plastic accessories such as insert baskets, silicone knob mats or lids must be decontaminated and disposed of. • The packing is recyclable. 6366-006 GB/2020-09 25 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
Drinking water quality 15, 18 22, 23 Electromagnetic ambient conditions Operating elements 10, 12 Operating temperature Operation Original parts 26 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
Page 27
Sonication 6, 7, 14, 15, 16, 17 Technical data Temperature Treatment instructions Type plate 6, 8 BANDELIN electronic GmbH & Co. KG www.bandelin.com Zertifi ziert nach Heinrichstraße 3 – 4 info@bandelin.com ISO 9001 12207 Berlin +49 30 768 80-0...
Page 29
Optional accessories Inset basket K 14, made of stainless steel, sieve cloth. Protects objects to be cleaned and prevents damages to the tank bottom. Optimum ultrasound transmission. Lid D 514, made of stainless steel, for use with inserted basket. Protects from exterior contamination. Condensation water is discharged in the oscillating tank.
Page 30
For purposes of reproducibility, it is important that the test templates can be used. conditions remain constant: A PDF for downloading and a usage video are available at http:/ /bandelin.com/folientest/. • Filling the oscillation tank to the filling level mark • Temperature of the sonication fluid • Degassing time •...
Page 31
(see video). Suitable foil testing frames can be ordered from Type Order no. BANDELIN electronic GmbH & Co. KG. DT 31/H, DT 52/H The foil testing frames are suitable for a wide range of tank FT 1...
Page 32
Note: The user instructions in this and other languages, as well as further information, are available on the supplied CD.