  • Page 1 User instructions BactoSonic Ultrasonic special bath Ultrasonic bath BS 14 6366-006 GB/2020-09...
  • Page 2 Copyright & limitation of liability This document may not be reproduced, either in full or in extracts, without prior approval of BANDELIN electronic GmbH & Co. KG, hereinafter referred to as BANDELIN. The German original is the binding version of this document. Any diff erence in the translation is not binding and has no legal eff ect.
  • Page 3 Operating sequence Identifi es instructions that are to be followed in the described  instructions sequence. 6366-006 GB/2020-09 3 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 4: Table Of Contents

    Cleaning and maintenance of the ultrasonic bath ............20 Cleaning and care ......................20 Disinfection ........................20 Positioning / Storage ....................20 Maintenance and repair ....................21 4 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 5 Taking the unit out of service ..................25 Key words ........................26 Informative appendices Scope of supply BactoSonic 14.2 Optional accessories Foil test 6366-006 GB/2020-09 5 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 6: Product Description

    This produces an especially homogeneous and uniform ultrasound fi eld in the bath volume for constantly reproducible results. 6 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 7: Purpose

    Purpose Gentle separation of biofi lms (main application) The BactoSonic ultrasonic bath may be used to detach biofi lms gently from the surface of infected implants, as part of the scientifi cally-funded "Processing of implants using sonication methods". The microorganisms that are obtained in this manner are available for analysis following cultivation and make a prompt diff...
  • Page 8: Ce Conformity

    In order to improve the eff ect, the ultrasound is modulated whereby, depending upon the ultrasonic bath, a 4-fold -ultrasonic nominal output value is yielded as ultrasonic peak power. 8 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 9: Electromagnetic Ambient Conditions (Emc)

    During operation, portable or mobile HF communication systems in the vicinity of the ultrasonic bath should be turned off - their operation may be disrupted. 6366-006 GB/2020-09 9 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 10: Warning And Safety Precautions

    Advice for the medical fi eld • The ultrasonic bath is exclusively intended for use by medical skilled personnel. 10 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 11: Preparation

    • The ultrasonic bath must be positioned in such a way that disconnection from the power supply is easily possible. 6366-006 GB/2020-09 11 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 12: Start-Up

    • For foil tests, for degassing and cleaning, etc., the power selection switch must be set to 100% P. 12 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 13: Ultrasound

    • An “engaging” of the time switch is barely felt if mains voltage is not present, e.g. if the mains plug is disconnected or the fuse is blown. The time switch only works if mains voltage is present. 6366-006 GB/2020-09 13 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 14: Use

    For this purpose, the objects to be treated are placed in a basket and hung inside the oscillating tank which is fi lled with bath liquid. Bath fl uid 14 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 15: Instructions For Use

    • The fl uid in the oscillating tank must not exceed a maximum operating temperature of 100°C. MILLNER, R.: Wissenspeicher Ultraschalltechnik, Fachbuchverlag publishing house, Leipzig 1987 6366-006 GB/2020-09 15 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 16: General Application

     Set the power selection switch to 100% P.  Switch ultrasound on for 10 min, see chapter 3.1.2 16 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 17  Verify that the objects to be treated are fully covered by fl uid.  With every object inserted, the fi ll level is to be monitored. 6366-006 GB/2020-09 17 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 18  After emptying the oscillating tank, rinse it thoroughly. Then dry with a soft cloth. For further care instructions, see chapter 5. 18 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 19: Further Information

    In every case, the statutory provisions and regulations of municipal wastewater plants are to be adhered to. Information is provided by municipal wastewater plants as well as by environmental agencies. 6366-006 GB/2020-09 19 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 20: Cleaning And Maintenance Of The Ultrasonic Bath

    During long periods of non-use, the ultrasonic bath is to be stored in a cool, dry location. The lid should be placed on top in order to protect the oscillating tank from outside contamination. 20 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 21: Maintenance And Repair

    Next, the value displayed is to be compared with the corresponding value in the technical data (chapter 1.4) (tolerances ± 20 %). 6366-006 GB/2020-09 21 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 22: Error Analysis

    The form can be downloaded from the Internet as a PDF fi le: www.bandelin.com / Service / Download ... 22 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 23: Exchanging Fuses

    - After inspection, exchange only the defective fuses. - Replacement fuses are located on the base plate.  Assembly in reverse order. 6366-006 GB/2020-09 23 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 24: Accessories

    Exceptions to this rule are special baskets and basket holders (e.g., K 6 and SH 7) that have been designed by BANDELIN in such a manner that they do not lie in the cavitation fi eld and do not damage the tank bottom.
  • Page 25: Consumable Materials - Not Applicable

    • Plastic accessories such as insert baskets, silicone knob mats or lids must be decontaminated and disposed of. • The packing is recyclable. 6366-006 GB/2020-09 25 / 32 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 26: Key Words

    Drinking water quality 15, 18 22, 23 Electromagnetic ambient conditions Operating elements 10, 12 Operating temperature Operation Original parts 26 / 32 6366-006 GB/2020-09 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 27 Sonication 6, 7, 14, 15, 16, 17 Technical data Temperature Treatment instructions Type plate 6, 8 BANDELIN electronic GmbH & Co. KG www.bandelin.com Zertifi ziert nach Heinrichstraße 3 – 4 info@bandelin.com ISO 9001 12207 Berlin  +49 30 768 80-0...
  • Page 28 Scope of supply BactoSonic 14.2 Implant box Implant box Implant box Implant box Implant box IB 5 IB 6 IB 10 IB 18 IB 20 (# 3208) (# 3219) (# 3244) (# 3227) (# 3237) Utensil holder Box holder Box holder...
  • Page 29 Optional accessories Inset basket K 14, made of stainless steel, sieve cloth. Protects objects to be cleaned and prevents damages to the tank bottom. Optimum ultrasound transmission. Lid D 514, made of stainless steel, for use with inserted basket. Protects from exterior contamination. Condensation water is discharged in the oscillating tank.
  • Page 30 For purposes of reproducibility, it is important that the test templates can be used. conditions remain constant: A PDF for downloading and a usage video are available at http:/ /bandelin.com/folientest/. • Filling the oscillation tank to the filling level mark • Temperature of the sonication fluid • Degassing time •...
  • Page 31 (see video). Suitable foil testing frames can be ordered from Type Order no. BANDELIN electronic GmbH & Co. KG. DT 31/H, DT 52/H The foil testing frames are suitable for a wide range of tank FT 1...
  • Page 32 Note: The user instructions in this and other languages, as well as further information, are available on the supplied CD.