Srne SR-EOV24-5.0S-S1 User Manual

Vertical energy storage system

Advertisement

File version: V1.2
SR-EOV24 Vertical Energy Storage System
User Manual
V1.2
Page 1 of 51

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SR-EOV24-5.0S-S1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Srne SR-EOV24-5.0S-S1

  • Page 1 File version: V1.2 SR-EOV24 Vertical Energy Storage System User Manual V1.2 Page 1 of 51...
  • Page 2: Range Of Application

    The installation and user manual of SR-EOV series is applicable to the installation and use of the following products: Applicable to the countries with Applicable to the countries with 220V mains voltage 110V mains voltage SR-EOV24-5.0S-S1 SR-EOV24-5.0U-S1 SR-EOV24-10.0S-S1 SR-EOV24-10.0U-S1 SR-EOV24-15.0S-S1 SR-EOV24-15.0U-S1 SR-EOV24-20.0S-S1...
  • Page 3: Safety Precautions

    File version: V1.2 1.3 Symbol Stipulations There may be following symbols herein, and their meanings are as follows. Symbols Description Indicate a hazard with a high level of risk which, if not avoided, will result in death or serious injuries. DANGER! Indicate a hazard with a medium level of risk which, if not avoided, could result in death or serious injuries.
  • Page 4: General Safety

    File version: V1.2 2.1 General Safety 2.1.1 Important Notice Before installing, operating and maintaining the device, please read this Manual first and follow the symbols on the device and all the safety precautions in this Manual. The matters indicated with "DANGER", "CAUTION", "ATTENTION" and "NOTICE" in this Manual do not represent all the safety matters to be observed, but are only the supplements to all the safety precautions.
  • Page 5: Personnel Safety

    File version: V1.2 In case of any fire, evacuate the building or equipment area and press the fire alarm bell or dial the fire call. Under any circumstances, re-entry into a burning building is strictly prohibited. DANGER! Under no circumstances should the structure and installation sequence of the device be changed without the manufacturer's permission.
  • Page 6: Personnel Requirements

    File version: V1.2 ● Do not short-circuit the battery terminals, because short-circuiting of the battery may cause combustion. ● The battery may pose a risk of causing electric shocks and large short-circuit currents. When using the battery, the following precautions should be paid attention to: a) The metal objects, such as watch and rings, shall be removed.
  • Page 7: Grounding Requirements

    File version: V1.2 ● All the electrical connections must meet the electrical standards of the country/region where the project is located. ● The cables prepared by users themselves shall comply with local laws and regulations. ● Special insulating tools should be used in high-voltage operations. ●...
  • Page 8: Product Introduction

    File version: V1.2 The operation and service life of the energy storage is related to the operating temperature. The energy storage should be installed at a temperature equal to or better than the ambient CAUTION temperature. 3 Product Introduction 3.1 Brief Introduction to Product SR-EOV is a new generation of household energy storage system with two output specifications of 220V and 110V, which can meet the diversified needs of global users.
  • Page 9: System Specifications

    File version: V1.2 3.2 System Specifications Battery Rated Output Rated Output Charge Max. PV Product model Frequency Energy Power Voltage (Vac) Current Power SR-EOV24-5.0S-S1 5.12kWh 3500W 230Vac 50Hz 0~80A 4000W SR-EOV24-5.0U-S1 5.12kWh 3500W 120Vac 60Hz 0~80A 4000W SR-EOV24-10.0S-S1 10.24kWh 3500W...
  • Page 10: Model Coding

    File version: V1.2 3.3 Model Coding The model coding of the energy storage battery is as follows: SR-EOV24-5.0S-S 1 ① ② ③ ④ ⑤ ⑥ Identifier Meaning Value EOH: horizontally-mounted ① Product type EOV: vertically-mounted EOS: wall-mounted 24: 24V system ②...
  • Page 11 File version: V1.2 SR-EOV24-5.0A-E 1 ① ② ③ ④ ⑤ ⑥ Identifier Meaning Value EOH: horizontally-mounted ① Product type EOV: vertically-mounted EOS: wall-mounted 24: 24V system ② System voltage 48: 48V system Energy storage capacity 5.0: The system capacity is 5kWh ③...
  • Page 12: Appearance Description

    File version: V1.2 3.5 Appearance Description 3.5.1 Dimentions Inverter dimensions(L*W*H):600*184*500mm Battery dimensions(L*W*H):600*184*610mm Base dimensions(L*W*H):680*184*80mm 3.5.2 Power Conversion System Module The power of power conversion system is 3.5KW. Page 12 of 51...
  • Page 13 File version: V1.2 ① ② ③ ④ LED indicator Operation keys Inverter ON/OFF ⑤ ⑧ RS485-2 Dry contact ⑥ ⑦ RS485-1 (Connect battery) (Start generator) ⑨ ⑩ ⑪ ⑫ PV input port AC output port AC input port PV input switch ⑬...
  • Page 14 File version: V1.2 3.5.3 Energy Storage Battery Module ① ② ③ ④ Turn On/Off LED( SOC) LED(ALM) LED(RUM) ⑦ ⑧ RS485-1 ⑤ ⑥ Address RS232 (Connect inverter) (Connect inverter) ⑨ ⑩ RS485-2 RS485-2 ⑪ ⑫ Dry contact Reset (Connect other battery) (Connect other battery) ⑬...
  • Page 15: Application Scenarios

    BMS system, which can be easily expanded and can be combined into 20Kwh battery pack at most. The battery storage can be combined with SRNE brand inverter to form an off-grid photovoltaic system, which can solve the problem of electricity consumption in areas without electricity.
  • Page 16 File version: V1.2 When the mains is disconnected or stops working, the battery supplies power to the load through the power module. 4.1.2 Application Scenarios with Only Photovoltaic but No Mains Power During the day, the photovoltaic directly supplies power to the loads while charging the battery. At night, the battery supplies power to the loads through the power module.
  • Page 17 File version: V1.2 4.1.3 Complete Application Scenarios During the day, the mains and photovoltaic simultaneously charge the battery and supply power to the loads. At night, the mains supplies power to the loads, and continues to charge the battery, if the battery is not fully charged.
  • Page 18: System Installation

    File version: V1.2 4.2 Load Working Mode Load working mode Inverter setting Description switching to the Mains when the PV fails or the battery is lower PV priority mode than the set value of parameter Mains priority mode, switching to inverter only when the mains Mains priority mode fails.
  • Page 19 File version: V1.2 Picture Item Quantity Specification Source Inverter Inverter 3.5kW/24V,110V/220V Package Battery Battery 5.12kWh/25.6V Package Inverter Base 680*184*80mm Package Battery Mounting Frame 80*44mm Package Mounting Frame Battery 2*(N+1) M8*60 expansion bolt Screw Package Battery Screw M5*10 Package Battery Fixing screw M6*35 Package Battery...
  • Page 20 File version: V1.2 5.2 Preparation of Tools and Meters Types Tools and meters Installation tool Personal protective equipment 5.3 Selection of Installation Location 5.3.1 Basic Requirements ● When the energy storage is running, the temperature of the case and the radiator will be high. Therefore, do not install them in a place that is easy to touch.
  • Page 21: Installation Space Requirements

    File version: V1.2 ● The energy storage cannot be installed forwardly, horizontally, inversely, backwardly or sideways. ● When drilling holes on walls or ground, the goggles and protective gloves shall be worn. ● During drilling, the device should be shielded to prevent debris from falling into the device. After drilling, the debris shall be cleaned up in time.
  • Page 22: Device Installation

    File version: V1.2 5.4 Device Installation 5.4.1 Installation Location Selection Determine the installation location, please choose a flat ground and a solid wall as the installation location. First, determine the installation position of the base, the fixed size is 648mm. Second, determine the installation position of the battery and inverter.
  • Page 23 File version: V1.2 According to the hole position, drill 2 holes on the ground and 4 holes on the wall, φ8, depth 45~50mm. Tap the M8 screw into the above hole and screw on the nut. 5.4.3 Mounting the base Fasten the base to the expansion screw.
  • Page 24 File version: V1.2 5.4.5 Install Inverter The installation method of the inverter is the same as that of the battery. Page 24 of 51...
  • Page 25: Electrical Connection

    File version: V1.2 6 Electrical Connection Before electrical connection, please ensure that the switches of the energy storage are in the "OFF" state. Otherwise, the high voltage of the device may cause electric shock. DANGER! The operations related to electrical connections must be carried out by professional electrical technicians.
  • Page 26 File version: V1.2 Power Cable Power Cable ground screw Page 26 of 51...
  • Page 27 File version: V1.2 6.2.3 Connecting Signal Line The signal line delivered with the product together shall be used to connect RS485-2 interface for each battery module. The inverter communication interface connects the 485-2 and the 485-1 interface of the battery. Signal Cable Page 27 of 51...
  • Page 28: Connecting Ac Input

    File version: V1.2 6.2.4 Energy Storage Battery Module Address Setting If multiple energy storage battery modules are used in parallel, the address of the energy storage battery module needs to be set. The address is set to 0~3, and the address of each module cannot be repeated. The address of the battery connected to the inverter must be set as 0.
  • Page 29: Wiring Specifications

    File version: V1.2 6.3.2 Connecting AC Output According to the cable sequence and terminal position shown in the figure below, correctly connect the AC output cable. When wiring, please pay attention to L and N and avoid short-circuit. 6.3.3 Connecting Photovoltaic Input According to the cable sequence and terminal position shown in the figure below, correctly connect the PV input cable.
  • Page 30: System Debugging

    File version: V1.2 7 System Debugging 7.1 Inspections Before Power-On Inspection items Acceptance criteria Validation The energy storage is installed The installation is correct, secure and reliable. □Yes □No in place The installation environment The installation space is reasonable and the □Yes □No meets requirements...
  • Page 31 File version: V1.2 7.2.2 Power-On of Energy Storage Battery Module After turn on the battery input breaker switch and confirmation, turn on the switch of the energy storage battery module. If there are multiple modules, please turn on the power switch one by one according to the address sequence.
  • Page 32 File version: V1.2 High temperature, Over Current Normal Blinking3 Alarm Blinking3 Blinking3 Discharging Over Discharge Protection Over Current,Short Current LED blinking description Blinking LED ON LED OFF Blinking1 0.25S 3.75S Blinking2 0.5S 0.5S Blinking3 0.5S 1.5S 7.2.3 Capacity Indicator Capacity indicator LED 0~25% 25~50% 50~75%...
  • Page 33 File version: V1.2 7.2.5 Inverter LED And Button Function Description After the power module works normally, the indicator lights are described as follows: Indicators introduction Indicator lights Color State Description Always ON Mains output AC/INV Yellow Blinking Inverter output Blinking The battery is being charged CHARGE Green...
  • Page 34 File version: V1.2 7.2.6 Inverter Real-time Data Viewing Method On the LCD main screen, press the “UP” and “DOWN” buttons to scroll through the real-time data of the machine. Parameters on the left side of the screen Parameters on the right side of the screen LCD Screen Introduction LCD Screen...
  • Page 35 File version: V1.2 7.2.7 PCS Parameter Adjustment allow Settings Parameter name Description adjustment ( default ) [00] Exit setting menu Exit the setup menu PV priority mode, switching to the Mains when the PV fails or the battery is lower than the set value of parameter [04].
  • Page 36 File version: V1.2 allow Settings Parameter name Description adjustment ( default ) When the parameter [01] =SOL/SBU, the battery voltage is higher than the Utility to Battery [05] 27.6V set value, and the output is switched Power Setpoint from the mains to the inverter. Setting range: 24V~30V.
  • Page 37 File version: V1.2 allow Settings Parameter name Description adjustment ( default ) Boost charge voltage setting; the Battery boost setting range is 24V~29.2V, with step [09] 28.4V charge voltage of 0.2V; it is valid for user-defined battery and lithium battery. Boost charge maximum time setting, which means the maximum charging time to reach the set voltage of...
  • Page 38 File version: V1.2 allow Settings Parameter name Description adjustment ( default ) step of 0.2V. It is valid for user- defined battery and lithium battery. Battery discharge limit voltage; when the battery voltage is lower than the point, the output is turned off Battery discharge [15] 23.2V...
  • Page 39 File version: V1.2 allow Settings Parameter name Description adjustment ( default ) After the power saving mode is enabled, if the load is null or less than 50W, the inverter output is turned off after a delay for a certain period of time.
  • Page 40 File version: V1.2 allow Settings Parameter name Description adjustment ( default ) when over load to the Mains when the inverter is overloaded. It is enabled to automatically switch to the Mains when the inverter is overloaded. AC Out 230Vac Setting range 0~80A Max AC charger [28] current...
  • Page 41: System Maintenance

    File version: V1.2 7.3 Install The Cover Plate When all wiring is complete and the system is operating normally, close the side cover. 8 System Maintenance 8.1 System Power-Off After the system is powered off, the case still has residual power and heat, which may cause electric shocks or burns.
  • Page 42: Routine Maintenance

    File version: V1.2 8.2 Routine Maintenance To ensure the long-term and good operation of the energy storage system, it is recommended to perform the routine maintenance as described in this section. Items Methods Maintenance interval Check if the radiator is covered or dirt on a regular Once every six months to one System cleanliness basis.
  • Page 43: Troubleshooting

    File version: V1.2 8.3 Troubleshooting 8.3.1 Fault Code and Handling Methods Whether it affects Fault code Fault name Description the output or not 【01】 BatVoltLow Battery undervoltage alarm Battery discharge average current overcurrent 【02】 BatOverCurrSw software protection 【03】 BatOpen Battery not-connected alarm 【04】...
  • Page 44 File version: V1.2 8.3.2 Common Faults and Handling Methods Faults Handling measures Check if the battery air switch or the PV air switch has been closed; if the No display on the screen switch is in the "ON" state; press any button on the screen to exit the screen sleep mode.
  • Page 45 File version: V1.2 – The corrosive organic solvents, gases and other substances shall be kept away. – Exposing to direct sunlight shall be avoided. – The distance from the heat source should not be less than two meters. 5. When being stored, the battery shall be disconnected from the external connection. If there is an indicator light on the battery panel, the indicator light shall be off.
  • Page 46: Device Cleaning

    File version: V1.2 8.5 Device Cleaning It is recommended to clean and maintain the product from time to time. When cleaning, the dust and stains on the product shall be removed with a piece of soft dry cloth or vacuum cleaner, especially when cleaning the heat dissipation and air vents on both sides of the product.
  • Page 47: Technical Data

    File version: V1.2 9 Technical Data 9.1 Power Module Data SR-EOV24-3.5S-C0 SR-EOV24-3.5U-C0 Rated Output Power 3500W 3500W Maximum Peak Powe 6000VA 6000VA Power Factor Battery Rated Output Voltage (Vac) 230Vac 120Vac Inverter Frequency 50Hz 60Hz Auto Switch Period <10ms <10ms <3% <3% Maximum AC Charge Power...
  • Page 48 File version: V1.2 9.2 Battery Module Data Battery Type LiFePO4 Battery Energy 5.12kWh Battery Capacity 200AH Battery Rated Voltage 25.6V Battery Working Voltage Range 22.4 ~ 28.8V Maximum Charging Current 150A Maximum Discharging Current 150A Parallel Quantity Designed Life-span 5000 Charge:0 ~...
  • Page 49: Product Dimensions

    File version: V1.2 10 Product Dimensions and Packaging 10.1 Product Dimensions The external dimensions of the inverter module is 600*184*500mm,the external dimensions of the energy storage battery module is 600*184*500mm,the external dimensions of the base module is 680*184*80mm. 10.2 Package Dimensions The packaging size of a single energy storage battery module and Inverter module is 700*690*275mm.
  • Page 50: Packaging List

    File version: V1.2 10.3 Packaging List Picture Item Quantity Specification Source Inverter Inverter 3.5kW/24V,110V/220V Package Battery Battery 5.12kWh/25.6V Package Inverter Base 680*184*80mm Package Battery Mounting Frame 80*44mm Package Mounting Frame Battery M8*60 expansion bolt Screw Package Battery Screw M5*10 Package Battery Fixing screw M6*35...
  • Page 51 File version: V1.2 Battery Power cable 560mm,4AWG Package Battery Signal cable 700mm Package Inverter User Manual Package Page 51 of 51...

Table of Contents