Installation and Operation Manual
Simplus Sulfur Removal Filters
with
263/742 Logix Control Valve
And Vortech Distributor
July 2008

Advertisement

loading
Need help?

Need help?

Do you have a question about the SIMPLUS 744 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Master Water Conditioning SIMPLUS 744

  • Page 1 MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual Simplus Sulfur Removal Filters with 263/742 Logix Control Valve And Vortech Distributor July 2008...
  • Page 2 Table of Contents Page Topic Description Model # and Packaging Packaging Information Component Packaging Packaging Description Description Filter System System Positioning Filter Tank Loading Filling with Media MBA Logix Control Valve Valve Description Logix 263/742 Control Valve Attaching Valve to Tank Figure 1 &...
  • Page 3 Installation and Operating Instructions for 263/742 Logix Top Mount Simplus Filter Model #: _______ SIMPLUS 744 ½ CF Sulfur Removal Filter _______ SIMPLUS 948 1 CF Sulfur Removal Filter _______ SIMPLUS1040 1 CF Sulfur Removal Filter _______ SIMPLUS 1054 1.5 CF Sulfur Removal Filter...
  • Page 4 System Description: The Simplus tank has a Logix top mounted automatic control valve with an electronic time clock to initiate regeneration. The Logix Valve is constructed of non-corrosive Noryl material and is rated at a maximum working water pressure of 100 psi. It uses a 742 microprocessor based timer to actuate regeneration in the following ways: a.
  • Page 5 Logix Control Valve: 1. When facing the front of the Logix timer, the inlet connection (Figure 1) is located on the left and the outlet connection is on the right. The control valve's inlet and outlet connections are either 1” copper or PVC equipped with gasket and nut.
  • Page 6 Service and Drain Piping: 1. Pipe Filter into the service lines .The inlet and outlet connections of the control valve are 1” copper or PVC and are located on the back of the valve body. As you face the timer the inlet is on the left and the outlet is on the right.
  • Page 7 224 Shoemaker Rd. Pottstown, PA 19464 Typical Piping Layout Treated water Air Gap Drain Untreated to outside Master Water Conditioner Well Tank Overflow fitting to floor drain gravity Chlorine Untreated Tank water from well NOTE: All Master Water Conditioners must be installed after the well tank or water meter if its public water supply.
  • Page 8 Electrical Requirements: Always follow all local electrical codes when installing our water treatment equipment. 1. Provide an 120v/60Hz properly grounded dedicated electrical Outlet. (It’s very important that the polarity be correct) Avoid using outlets that are switch controlled. 2. Maximum amperage required is 5 amps. 3.
  • Page 9 Logix Control Valve Electrical Connection: Note: Do not touch the wiring harness between the Logix timer and the motor, it’s positioning is critical and therefore already installed at the factory. 1. Remove plastic control valve cover by spreading sides while lifting. 2.
  • Page 10 2. When water is running steadily at the drain, open the bypass valve’s inlet and outlet to their maximum position. Simultaneously press the SET and UP buttons on the controller for 1 second then release, the motor will advance the cam to C2. Once C2 is displayed simultaneously press the SET and UP buttons on the controller for 1 second then release, the motor will advance the cam to C3.
  • Page 11 Day of Week Setting 1) Press the SET button. The screen will show the Day of Week in blinking triangle. 2) To change the Day of Week, use the UP or DOWN arrows. 3) Press the SET button. Time of Regeneration Setting (the factory default is 1 AM) 1) Press the SET button.
  • Page 12 Troubleshooting Problem: Rotten egg odor returns Possible Cause Solution Media bed may be fouled Add 1 qt. of chlorox bleach and manually regenerate unit Problem: Water conditioner fails to regenerate. No treated water. Possible Cause Solution Faulty electrical supply Verify that electrical power is getting to the outlet Low inlet water pressure Verify a minimum 30 psi inlet water...
  • Page 13 Problem: Insufficient chlorine draw Possible Cause Solution Partially clogged injector or injector Inspect and clean injector and/or screen. injector screen assembly. Insufficient water pressure. Verify a minimum 30 psi inlet water pressure Excessive back pressure on Reduce drain line elevation to height injector due to elevated drain line.
  • Page 14 Problem: Loss of Water Pressure Possible Cause Solution Fouled media bed due to iron. Clean control valve and mineral bed with cleaner. Slots in riser pipe or laterals are Inspect and clean distributor pipe slots filled with media fines. as needed. Insufficient well pump Check well pump gpm (gallons per minute)
  • Page 19 Congratulations on your purchase! Thank you for choosing Master Water Conditioning equipment. System Description: You have purchased a state of the art water conditioning unit which removes sulfur odor from your raw water supply . It’s simple, with very little maintenance.
  • Page 20 To Set the Simplus Timer follow the steps below: Time of Day Setting 1) Press the SET button. The screen will show the Time of Day in blinking numbers. 2) To change the Time of Day, use the UP or DOWN arrows. 3) Press the SET button.
  • Page 21 All claims must be submitted in writing to Master Water Conditioning Corporation at 224 Shoemaker Road, Pottstown, Pennsylvania 19464 within thirty (30) days from the discovery of the defect.