Unevenly Formed Spine; Replacing Fuses; Seeking Assistance - Watkiss SpineMaster Operating Manual

Hide thumbs Also See for SpineMaster:
Table of Contents

Advertisement

Caution
UNEVENLY FORMED
SPINE

REPLACING FUSES

Warning
SEEKING
ASSISTANCE
10
Take great care not to damage the black plastic sensors.
Avoid using a metal implement, as this may damage the
mechanism.
Switch the unit ON again and it will be ready for operation.
If the spine is well formed at only one end, check that the
booklet is being placed squarely onto the latch. If the
booklet is at an angle, uneven forming will result.
Some stocks may require Double Pass Mode to achieve
an even result.
Your SpineMaster is fitted with two fuses at the mains
input. If either of these fail, the SpineMaster will not
operate.
The SpineMaster uses double-pole/neutral fusing (i.e.,
two fuses), so when changing fuses always first discon-
nect the machine from the mains electricity supply by
switching OFF and unplugging the machine.
• Switch the SpineMaster OFF and unplug the mains
input lead. Open the flap on the fuse holder.
• Pull out each fuse casing in turn and check the fuse.
• Replace if necessary with a fuse of the correct spec-
ification, as detailed below.
Reference
230V machines:
730-016 Fuse, 1.25" (32mm) 5.0A HRC-Quick Acting F
115V machines:
730-020 Fuse, 1.25" (32mm) 10.0A HRC (Quick Acting, F)
If you require assistance with your Watkiss SpineMaster,
please contact your local Watkiss supplier or the Watkiss
Service Department.
Watkiss SpineMaster Operator Guide - Issue 1 - June 2000