en Cleaning and servicing
To allow the detergent solution to
6.
flow out into the container, remove
the pump cap carefully.
Cleaning the drain pump
Note: Please read the safety informa-
tion → Page 4 to ensure that you use
the appliance safely.
Requirement: The drain pump is
empty. → Page 37
Because water may remain in the
1.
drain pump, remove the pump cap
carefully.
38
Clean the inside and the thread on
2.
the pump cap and pump housing.
Make sure that the impeller in the
3.
drain pump can be turned.
Insert the pump cap and screw it
4.
on.
90°
The handle on the pump cap must
be in a vertical position.
Insert the maintenance flap and
5.
lock it into place.