Download Print this page

EMS FireCell FC-171-001 Installation Manual page 2

Wireless sounder beacon

Advertisement

Configuration continued
Sounder tone (Set on sounder beacon)
Switches 1-5 on the 7 way switch are used to
configure the sounder tone.
All
32
available
configurations are shown
in the tone table.
Default setting: primary tone 5
Volume/flash rate
(Set on sounder beacon)
Switches 6 and 7 are used to configure the
volume and flash rate.
SWITCHES
6 & 7
ON
6
ON
6
Sounder Beacon
ON
OFF
5
6
7
1
2
3
4
6
OFF
6
Default setting: high volume / 1 Hz flash rate
Audio monitoring
(Set on wireless module)
The primary and secondary stage sounder
tones can be monitored. If enabled and no
audio is detected within 10 seconds upon
sounder activation, a fault is indicated at the
control panel.
SWITCHES
1 & 2
ON
ON
1
2
www.emsgroup.co.uk
ON
OFF
Wireless Sounder Base
1
2
ON
IDENT
OFF
PRESS HERE TO
1
2
LOG ON
OFF
OFF
Default setting: audio monitoring disabled
Specification
Operating temperature
-10 to +55 °C
Storage temperature
5 to 30 °C
Humidity
0 to 95% non-condensing
Supply
3x AA alkaline (Panasonic LR6AD Powerline / Varta 4006
Industrial) 3x C alkaline (Panasonic LR14AD Powerline / Varta
4014 Industrial)
CAUTION!
Fitting of an incorrect battery type invalidates the product certification and may result in poor
performance.
Sounder output
94 to 97 dB(A) at 1 m (as dispatched).
Low setting reduces volume by 7 dB.
IP rating
IP54
Operating frequency
868 MHz
Output transmitter
power
Auto adjusting 0 to 14 dBm (0 to 25 mW)
Beacon element voltage
17 to 60 VDC operating at 18 VDC
Beacon element
current (max.)
45 mA at 1 Hz flash rate
Flash rate
0.5 Hz / 1 Hz (selectable)
Beacon
coverage
C-3-15 (ceiling mounted variant)
W-3.1-11.3 (wall mounted variant)
Dimensions (Ø x D)
120 x 145 mm
Weight
0.65 kg
Location
Type A: For indoor use
©2021 EMS Ltd. All rights reserved
SWITCHES
ON
O-O-O-O-O
1 2 3 4
ON
O-O-O-O-|
1 2 3 4
ON
O-O-O-|-O
1 2 3 4
ON
O-O-O-|-|
1 2 3 4
ON
O-O-|-O-O
1 2 3 4 5
Sounder Beacon
ON
O-O-O-|-|
1 2 3 4
ON
ON
5
6
7
1
2
3
4
O-O-|-O-|
1 2 3 4
ON
O-O-|-|-|
1 2 3 4
ON
O-|-O-O-O
1 2 3 4
ON
O-|-O-O-|
1 2 3 4
ON
O-|-O-|-O
1 2 3 4
ON
O-|-O-|-|
FLASH
1 2 3 4
VOLUME
ON
RATE
O-|-|-O-O
1 2 3 4
ON
LOW
1Hz
ON
O-|-|-O-|
7
1 2 3 4
ON
O-|-|-|-O
LOW
0.5Hz
OFF
1 2 3 4
7
ON
O-|-|-|-|
ON
1Hz
HIGH
1 2 3 4
7
ON
|-O-O-O-O
1 2 3 4
HIGH
0.5Hz
OFF
ON
7
|-O-O-O-|
1 2 3 4
ON
|-O-O-|-O
1 2 3 4
ON
|-O-O-|-|
1 2 3 4
ON
|-O-|-O-O
1 2 3 4
ON
|-O-|-O-|
1 2 3 4
ON
|-O-|-|-O
1 2 3 4
ON
|-O-|-|-|
1 2 3 4
ON
|-|-O-O-O
1 2 3 4
PRIMARY
SECONDARY
ON
TONE
TONE
|-|-O-O-|
1 2 3 4
MONITORED
MONITORED
ON
|-|-O-|-O
1 2 3 4
ON
|-|-O-|-|
1 2 3 4
ON
|-|-|-O-O
1 2 3 4
ON
|-|-|-O-|
1 2 3 4
ON
|-|-|-|-O
1 2 3 4
ON
|-|-|-|-|
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
PRIMARY
1-5
TONE
TONE TYPE
1.
1.
18
5
2.
2.
1
5
3.
1
5
4.
5
5.
6.
1
5
7.
1
5
8.
8.
9
5
9.
9.
1
5
10.
19
5
11.
1
5
12.
1
5
13.
1
5
14.
14.
18
5
15.
1
5
16.
1
5
17.
17.
1
5
18.
18.
1
5
19.
19.
18
5
20.
19
5
21.
19
5
22.
1
5
23.
1
5
24.
1
5
25.
1
5
26.
18
5
27.
18
5
28.
1
5
29.
1
5
30.
1
5
31.
1
5
32.
8
Regulatory Information
Manufacturer
Year of manufacture
Certification
Certification body
CPR DoP
Approved to
European Union
directives
Page 2 of 2
TONE DESCRIPTION / APPLICATION
970Hz
800Hz/970Hz @ 2Hz
800Hz - 970Hz @ 1Hz
970Hz 1s OFF / 1s ON
970Hz, 0.5s / 630Hz, 0.5s
554Hz, 0.1s / 440Hz, 0.4s (AFNOR NF S 32 001)
500 - 1200Hz, 3.5s / 0.5s OFF (NEN 2575:2000)
420Hz 0.625s ON / 0.625s OFF (Australia AS1670 Alert tone)
500 - 1200Hz, 0.5s / 0.5s OFF x 3 / 1.5s OFF (AS1670 Evacuation)
550Hz / 440Hz @ 0.5Hz
970Hz, 0.5 ON / 0.5s OFF x 3 / 1.5s OFF (ISO 8201)
2850Hz, 0.5s ON / 0.5s OFF x 3 / 1.5s OFF (ISO 8201)
1200Hz - 500Hz @ 1Hz (DIN 33 404)
400Hz
550Hz, 0.7s / 1000Hz, 0.33s
1500Hz - 2700Hz @ 3Hz
750Hz
2400Hz
660Hz
660Hz 1.8s ON / 1.8s OFF
660Hz 0.15s ON / 0.15s OFF
510Hz, 0.25s / 610Hz, 0.25s
800 / 100Hz 0.5s each (1Hz)
250Hz - 1200Hz @ 12Hz
500Hz - 1200Hz @ 0.33Hz
2400Hz - 2900Hz @ 9Hz
2400Hz - 2900Hz @ 3Hz
800Hz - 970Hz @100Hz
800Hz - 970Hz @ 9Hz
800Hz - 970Hz @ 3Hz
800Hz, 0.25s ON / 1s OFF
500Hz - 1200Hz, 3.75s / 0.25s OFF (AS2220)
Carrier Manufacturing Polska Sp. Z o.o. Ul. Kolejowa 24.
39-100 Ropczyce, Poland
See devices serial number label
14
0905
0359-CPR-00292
See part listing for associated products:
EN54-3:2001. Incorporating Amendments Nos. 1 and 2. Fire
detection and fire alarm systems. Part 3: Fire alarm devices -
Sounders.
[1]
EN54-23:2010. Fire detection and fire alarm systems. Part
23: Fire alarm devices. Visual alarm devices.
EN54-25:2008. Incorporating corrigenda September 2010
and March 2012. Fire detection and fire alarm systems. Part
25: Components using radio links.
EMS declares that this device is in compliance with Directive
2014/53/EU. The full text of the EU declaration of conformity
is
available
at
the
www.emsgroup.co.uk
2012/19/EU (WEEE directive):
Products marked with this symbol cannot be disposed of as
unsorted municipal waste in the European Union. For proper
recycling, return this product to your local supplier upon
purchase of equivalent new equipment, or dispose of it at
designated collection points. For more information see
www.recyclethis.info
Dispose of your batteries in an environmentally friendly
manner according to your local regulations.
TSD066-99 Iss 8 23/11/2021 AJM
SECONDARY
TONE
18
1
1
1
4
1
1
9
1
19
1
1
1
18
1
1
1
1
18
19
19
1
1
1
1
18
18
1
1
1
1
8
[1]
[2]
following
internet
address:

Advertisement

loading

This manual is also suitable for:

Firecell fc-171-002Firecell fc-315-ca1Firecell fc-315-ca2Firecell fc-315-wa1Firecell fc-315-wa2