1) Generator Switch
The generator starts when the engine oil switch and flameout switch are on and the
choke is off.
2) Oil Indicator
When the oil in the crankcase is below the
safety line, the oil protection system will
automatically shut down the engine, and the oil
alarm indicator will be on; only when the oil is
filled to the oil level can the engine be started
again.
Tip: if the engine stops or fails to start, press
the switch to the "on" position, and then pull
the start handle. If the oil indicator flashes for a
few seconds, the oil capacity is insufficient. Fill
in oil and restart.
3) Overloaded Indicator
When the overload light is on, the generator detects that the output of the
connected electrical equipment has been overloaded, which causes the inverter to
overheat or the AC current to increase. At this time, the AC protector works and
stops the generator to protect the generator and the connected electrical equipment.
The AC indicator (green) is off and the overload indicator (red) is on, but the
engine will not stop.
When the overload indicator is on and the unit has no output, please take the
following measures:
1. Turn off the switch of the connected electrical equipment or pull out the
plug.
2. Press the self recovery reset button on the panel, and the operation indicator
on the panel turns green.
3. Reduce the load power of electrical equipment ≤ 1.1 times the rated output
power.
4. Press the idle switch to "off".
5. Turn on the power switch or plug in the power plug.
Tip: when using the electrical equipment with high starting current (such as
compressor, submersible pump, etc), the overload indicator light is just started It
may light up for a few seconds, but this is not the fault mentioned earlier.
Engine oil lamp
7
Overload light