Advertisement

Quick Links

INVERTER GENERATOR
OPERATIONAL MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Elverk CCMAX 1200i

  • Page 1 INVERTER GENERATOR OPERATIONAL MANUAL...
  • Page 2 It contains how to use generator set in proper way, please read the operational manual before use it. Safe & proper operation help the generator set in normal running and prolongs its life span. The issuing of technical data and drawings in this operational manual are all in accordance with the newest products.
  • Page 4: Table Of Contents

    1.Safety Insruction......................2.Component Identification.................... 3.Operation and Control System..................4.Start Generator......................5.Stop The Generator....................6.Use Generator......................7.Check Before Operation................... 8.Start Engine And Connect The Load................ 9.Maintenance......................10.Storage And Transportation..................11.Trouble Shooting....................12.Circuit Diagram...................... 13.Parameter.......................
  • Page 5: Safety Insruction

    1.Safety Insruction...
  • Page 8: Component Identification

    2.Component Identification 1.Fuel tank cap 2.Control panel 3.Control panel 4.Recoil starter 5.Left shell 6.Handle base grip 7.Muffler cover 8.Appearance 9.Engine oil 10.Choke valve 11.Oil switch cover plate plate cover plate 1 ) Control Panel 5.Energy- 1.Running light 2.Overload light 3.Engine oil lamp 4.Engine switch saving switch 6.DC breaker 7.Earthing terminal 8.AC socket...
  • Page 9: Operation And Control System

    1) Generator Switch The generator starts when the engine oil switch and flameout switch are on and the choke is off. 2) Oil Indicator When the oil in the crankcase is below the safety line, the oil protection system will automatically shut down the engine, and the oil alarm indicator will be on;...
  • Page 10 4) AC Indicator AC Indicator 5) DC Protector 6) ECO Switch 4350...
  • Page 11: Start Generator

    7) Fuel Tank Cap Turn counter clockwise to remove the tank cap. 8) Grounding Terminal When the ground terminal is connected to the ground wire, to prevent electric shock. When the electrical equipment is grounded, the generator must be grounded. Grounding terminal 4.Start Generator 1) Turn the fuel tank cap knob to “ON”.
  • Page 12: Stop The Generator

    4) Stabilize the generator and pull the handle outward to make the generator run. 5) Turn the choke to “ON” to the left. Notice: when pulling the hand starter, grasp the handling handle of the generator to prevent the generator from overturning. 5.Stop The Generator 1) Stop all the electric equipment.
  • Page 13 2)Generator Wire Connection...
  • Page 14 3)Generator Grounding Before starting the generator, it should be confirmed that the total power of load electrical appliances should not exceed the rated power of the generator. Overload working will shorten the generator life . If there are several loads or equipments connected on the generator at the same time, make sure firstly start the equipment that with highest starting current, then middle one, finally to the lowest starting current one.
  • Page 15 Output Powe 1000W 800W 350W...
  • Page 16 6)Used in High Altitude Area If the carburetor which is suitable for high altitude be assembled on the generator that is used in low altitude, the rare mixed gas will make the generator power down, too hot or serious damage.
  • Page 17: Check Before Operation

    7.Check Before Operation span 104F Synthetic 5W/30 oil is recommended Fuel the highest level...
  • Page 18: Start Engine And Connect The Load

    8.Start Engine And Connect The Load l) Starting Engine (4) Turn the choke handle to the right to the “close” position. 2) Connected To The Load When using electrical equipment that needs large starting current, such as inductive and capacitive loads, the fuel saving switch must be set in “off ” position;...
  • Page 19 3) Overload Processing or AC output current increases...
  • Page 20 1)Oil Change 0.33 Skin long -term and regular exposure to oil may cause skin cancer. Although this is not necessarily necessary, it is recommended to use soap and water to wash the skin immediately and thoroughly. From an environmental point of view, please deal with the waste oil produced after use. We strongly recommend that you put the waste oil into a sealed container and send it to a local service station or a waste oil recycling center.
  • Page 21: Maintenance

    2) Air Cleaner Mmaintenance ① Remove the button of the air filter cover and open the air filter cover. Check the filter element of air filter to ensure it is in good condition and clean. ② If the foam filter is dirty, please clean the foam filter core: Clean and dry the filter element with solvent, drop a few drops of engine oil and squeeze it clean.
  • Page 22 Caution: Please use the appropriate calorie spark plug. 4) Fuel Tank Filter Caution: Be sure to tighten the tank cover. 5) Muffler Replace the muffler net cover.
  • Page 23: Storage And Transportation

    10.Storage And Transportation 1) Emptying Fuel Note: Do not connect any electrical equipment, the engine running time depends on the fuel tank in the remaining fuel. 2) Generator Transportation...
  • Page 24: Trouble Shooting

    11.Trouble Shooting The engine does not star 1) Fuel System. a) There is no fuel in the combustion chamber. b) There is no fuel in the fuel tank. c) Tubing is blocked. d) Something else get into the fuel valve. e) Carburetor is blocked.
  • Page 25: Circuit Diagram

    12.Circuit Diagram...
  • Page 26: Parameter

    13.Parameter Item Parameter Model 145F/P Type Single Cylinder, Four Stroke Bore×Stroke(mm) 45×36 Displacement(cc) Compression Ratio 8.5:1 Max.Power (kW) Rated Power (kW) 1.35 Ignition System Transistorized Magneto Engine Starting Mode Recoil Start Fuel Tank Capacity(L) Fuel Type E5/98 Oktan Lubrication Oil 0.33 Capacity(L) Noise dB (7m)

Table of Contents