Riello Vokera EASI-HEAT i User Instructions page 12

High efficiency combi boiler
Table of Contents

Advertisement

Flue Details (concentric 60-100)
Maximum horizontal flue length (60/100mm)
Maximum vertical flue length (60/100mm)
Efficiency
SEDBUK 2005 (%)
Emissions
CO2 @ maximum output (%)
CO2 @ minimum output (%)
CO @ maximum output (ppm)
CO @ minimum output (ppm)
NOx rating
Parameter
Seasonal space heating energy efficiency class
Water heating energy efficiency class
Rated heat output
Seasonal space heating energy efficiency
Useful heat output
At rated heat output and high-temperature regime (*)
At 30% of rated heat output and low-temperature regime (**)
Useful efficiency
At rated heat output and high-temperature regime (*)
At 30% of rated heat output and low-temperature regime (**)
Auxiliary electricity consumption
At full load
At part load
In Stand-by mode
Other parameters
Stand-by heat loss
Pilot flame energy consumption
Annual energy consumption
Sound power level, indoors
Emissions of nitrogen oxides
For combination heaters
Declared load profile
Water heating energy efficiency
Daily electricity consumption
Daily fuel consumption
Annual electricity consumption
Annual fuel consumption
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C
return temperature (at heater inlet).
NOTE (if the outdoor temperature sensor or the control panel, or even both devices, are present in the boiler)
With reference to the Delegated Regulation (EU) No. 811/2013, the information in the table can be used for completing the product
data sheet and the labelling for room heating appliances, for mixed heating appliances, for all those appliances for enclosed space
heating, for temperature control devices and solar devices:
ADDED DEVICES
OUTDOOR TEMPERATURE SENSOR
CONTROL PANEL*
OUTDOOR TEMPERATURE SENSOR + CONTROL PANEL*
(*) Set as ambient regulator
12
EASI-HEAT i 25C
5.85m
6.85m
EASI-HEAT i 25C
89.8
EASI-HEAT i 25C
9.0
9.0
140
10
class 6
EASI-HEAT i
Symbol
25C
-
A
-
A
Pnominal
19
ηs
93
P4
19,4
P1
6,5
η4
87,3
η1
98,5
elmax
32,0
elmin
12,0
PSB
3,0
Pstby
30,0
Pign
-
QHE
42
LWA
50
NOx
22
XL
ηwh
84
Qelec
0,133
Qfuel
23,183
AEC
29
AFC
18
CLASS
II
V
VI
EASI-HEAT i 29C
4.85m
5.85m
EASI-HEAT i 29C
90.0
EASI-HEAT i 29C
9.0
9.0
150
10
class 6
EASI-HEAT i
Unit
29C
A
-
A
-
24
kW
93
%
24,4
kW
8,2
kW
87,6
%
98,2
%
38,0
W
12,0
W
3,0
W
32,0
W
-
W
56
GJ
53
dB
22
mg/kWh
XL
84
%
0,152
kWh
23,306
kWh
33
kWh
18
GJ
BONUS
2%
3%
4%