Fault
Appliance door opens too
wide at the end of the pro-
gramme.

Error code / Fault display / Signal

Fault
E:21-60 will light up altern-
ately.
E:30-00 will light up altern-
ately.
E:31-00 will light up altern-
ately.
E:34-00 will light up altern-
ately.
E:32-00 will light up altern-
ately or indicator for water
supply lights up.
Cause
Door is not correctly adjus-
ted.
Wrong screws used to ad-
just the door gap.
Cause
Appliance has detected cal-
cified heating element.
Water protection system is
activated.
Water protection system is
activated.
Water is continuously run-
ning into the appliance.
Supply hose is kinked.
Water tap is turned off.
Water tap is jammed or
furred up.
The filters in the water con-
nection of the supply or
AquaStop hose are blocked.
Troubleshooting en
troubleshooting
Adjust the appliance door as de-
scribed in the installation instruc-
tions.
The door gap must be at least
70 mm - 100 mm.
Use size 4X30 bolts to adjust the
door gap.
The bolts are included in the scope
of supply.
If you use bolts that are too long,
this can deactivate the function of
automatic door opening.
troubleshooting
Descale the appliance.
1.
Operate the appliance with the Wa-
2.
ter softening system.
Turn off the water tap.
1.
Call "Customer Service"
2.
→ Page 60.
Turn off the water tap.
1.
Call "Customer Service"
2.
→ Page 60.
Turn off the water tap.
1.
Call "Customer Service"
2.
→ Page 60.
Install the supply hose without
kinks.
Turn on the water tap.
Turn on the water tap.
The flow rate must be at least 10 l/
min when the water supply is open.
Switch off the appliance.
1.
Pull out the mains plug.
2.
Turn off the water tap.
3.
Unscrew the water connection.
4.
Remove the filter from the supply
5.
hose