Download Print this page

3onedata IMC101B Series Quick Installation Manual page 2

Industrial media converter

Advertisement

supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【DIN-Rail Mounting】
The product adopts 35mm standard DIN-Rail mounting which
is suitable for most industrial scenes, mounting steps as
follows:
Step 1
Check if the DIN-Rail mounting kit is installed firmly.
Step 2
Insert the bottom of DIN-Rail mounting kit (one side
with spring support) into DIN-Rail, and then insert
the top into DIN-Rail.
Tips:
Insert a little to the bottom, lift upward and then insert
to the top.
Step 3
Check and confirm the products is firmly installed
on DIN-Rail, then mounting ends.
【Disassembling DIN-Rail】
Step 1
Device power off.
Step 2
After lift the device upward slightly, first shift out the
top of DIN-Rail mounting kit, and then shift out the
bottom of DIN-Rail, disassembling ends.
Note before powering on:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
and then plug the power supply plug contact and power
on.
Power OFF operation: First, remove the power plug,
and then remove the wiring section of terminal block.
Please pay attention to the above operation sequence.
【Power Supply Connection】
DC power supply
Model I and Model III provide 3-pin 7.62mm
pitch terminal block for 1 DC power input.
This power supply supports anti-reverse
connection Power supply range: 9 ~
48VDC. The pin definitions of power supply are shown as
follows:
Pin No.
1
2
Definition
V+
FG
AC power supply
Model II and Model IV provide 3 7.62mm
pitch terminal block for 1 power input.
Power supply range: 100~240VAC/DC.
The pin definitions of power supply are
shown as follows:
Pin No.
1
2
Definition
N/-
GND
【DIP Switch Settings】
Provide 4-bits DIP switch for function setting,
where "ON" is enable valid terminal. DIP switches
definition as follows:
DIP
Definition
Operation
1
Jumbo frame
Set the DIP to ON to enable jumbo
frame function
2
Broadcast
Set the DIP to ON to enable
storm
broadcast storm suppression
suppression
function
3
Set the DIP to ON to enable LFP
LFP
function, when one end of the
DIP
Definition
4
Flow control
【Checking LED Indicator】
The device provides LED indicators to monitor the device
working
status
troubleshooting; the function of each LED is described in the
table as below:
Indicate
LED
ON
3
PWR
OFF
V-
ON
Blinking
Link/Act
(1-2)
OFF
【Specification】
3
Panel
L/+
100M Copper Port
100M fiber port
100M SFP
Indicator
Switch Property
Backplane bandwidth
MAC Address Table
Power supply
Operation
copper port or fiber port
disconnects, close another port;
when the port is reconnected, open
another port.
Set the DIP to ON to enable flow
control function
with
a
comprehensive
simplified
Description
PWR is connected normally
PWR is disconnected or running
abnormally
Ethernet port is connected
The Ethernet interface is in a
network activity state.
Ethernet
port
is
is
connected
abnormally or disconnected
10/100Base-T(X),
RJ45,
Automatic Flow Control, Full/half
Duplex
Mode,
MDI/MDI-X
Autotunning
100Base-FX, optional SC/ST/FC
100Base-FX SFP slot
Power supply indicator, interface
indicator
1G
2K

Advertisement

loading