Mounting
16
5.2.1
Example of mounting with angle bracket (supplied by
customer)
 3
L-angle bracket; engineering unit: mm (in)
5.3

Weight

• Weight without water cooling jacket: max. 18 kg (39.69 lb)
• Weight with water cooling jacket (empty): max. 21 kg (46.31 lb)
• Weight with water cooling jacket (full): max. 25 kg (55.13 lb)
5.4

Installation requirements

5.4.1

Safety instructions

WARNING
L
Even when the source container is closed, it is possible that the Modulator FHG65 is
in the controlled area for ionizing radiation.
In this case, the Modulator FHG65 must be cordoned off and made inaccessible.
For this reason, observe the following sequence of steps when mounting the modulator
and source container:
1. Mount the Gamma Modulator FHG65 on the tank or pipe
2. Establish the electrical connection of the Gamma Modulator
3. If a water cooling jacket is provided:
 Connect the water supply
4. Mount the source container on the modulator and cordon it off
Gamma Modulator FHG65 Synchronizer FHG66
19.1 (0.75)
176 (6.93)
≥80 (3.15)
A0018531
Endress+Hauser