RBA1882-100-008 Installation
Rough Wall Opening for button assembly: 23mm Dia
Note: When mounting flush valve assembly in the ceiling or restricted space, vacuum breaker must be installed in the
vertical plane . Consult RBA or a qualified hydraulic consultant for advice.
FFL
•
Assemble Piezo button and Flush ring escutcheon on to Piezo. Ensure all components are securely fastened.
•
Pull Piezo cable through conduit from the bottom to the ceiling space where controller is to be mounted.
•
Mount Piezo/Indicator ring assembly on the wall with silicone.
•
Make electrical connections: Connect Half Flush piezo to Sensor A. Connect Full Flush piezo to Sensor B. Connect
Solenoid valve to Valve A. Connect the Power Pack to Power 24VAC.
16 of 20
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
184
SYDNEY | MELBOURNE | BRISBANE | PERTH | AUCKLAND
Australia 1300 788 778 www.rba.com.au | New Zealand 0800 722 111 www.rbagroup.co.nz
73
23mmø PENETRATION
FOR PIEZO BUTTON
40mm
FLUSH PIPE (Supplied by others)
FFL