The light source, metal halide lamp, in the LCD projector emits small
amounts of UV-Radiation.
AVOID DIRECT EYE AND SKIN EXPOSURE.
To ensure safety please adhere to the following:
1. Be sure to wear sun-glasses when servicing the
projector with the lamp turned "on" and the top
enclosure removed.
2. Do not operate the lamp outside of, the lamp
housing.
3. Do not operate for more than 2 hours with the
enclosure removed.
UV-Radiation and Medium Pressure Lamp Precautions
1. Be sure to disconnect the AC plug when replacing the lamp.
2. Allow one hour for the unit to cool down before servicing.
3. Replace only with same type lamp. Type MSFRl20S12H rated 8OV/12OW.
4. The lamp emits small amounts of UV-Radiation, avoid direct-eye contact.
5. The medium pressure lamp involves a risk of explosion. Be sure to follow installation instructions
described below and handle the lamp with care.
Note:
Since the lamp reaches a very high temperature during
units operation replacement of the lamp should be
done at least one hour after the power has been
turned off. (to allow the lamp to cool off.)
Installing the new lamp, make sure not to touch the
lamp (bulb) replace the lamp by holding its reflector
[Use original replacement only.]
DANGER! - Never turn the power on without the lamp to avoid electric-shock or
damage of the devices since the stabilizer generates high voltages at its start.